Research paper
Multiplex polymerase chain reaction for adenovirus and herpes simplex virus in eye swabs

https://doi.org/10.1016/0166-0934(95)01903-0Get rights and content

Abstract

Adenoviruses and herpes simplex virus (HSV) can cause clinically indistinguishable episodes of acute eye disease. Adenovirus infection is associated with nosocomial outbreaks and HSV may result in episodes of recurrent ocular inflammation. In a comparison of multiplex PCR for the two viral DNAs and virus isolation in cell culture, identical results were obtained for 18 of 20 specimens (positive for adenovirus in 5, HSV in 5, and negative in 8). One specimen was falsely negative for each viral DNA. Inclusion of human β-globin primers in the adenovirus-HSV reaction was precluded by a consequential 10–100-fold reduction in sensitivity for the two viral targets and by the failure of β-globin DNA amplification at the annealing temperature (45 °C) required to ensure detection of adenoviruses of serotypes 7 and 11 with the selected adenovirus primers. A single-target β-globin PCR gave positive results with 19 of the 20 specimens prepared by treatment with proteinase K lysis buffer, indicating the effectiveness of this simple DNA extraction procedure. Nonetheless, the availability of effective antiviral therapy for HSV made monitoring for extraction failure using human primers crucial to avoid false-negative results for HSV DNA. Adenovirus-HSV PCR has considerable potential for the rapid diagnosis of viral eye disease particularly if β-globin primers can be included in the reaction.

References (15)

There are more references available in the full text version of this article.

Cited by (39)

  • A multiplex PCR-based protocol for identification and quantification of Vibrio harveyi-related species

    2015, Aquaculture
    Citation Excerpt :

    The multiplex PCRs produced amplicons that were easily visible in agarose gels for template quantities ranging from 300 ng to 300 pg DNA, but products were not visible when the template quantity was reduced to 30 pg DNA (data not shown). The 100-fold reduction in sensitivity of the multiplex PCR compared to the corresponding monoplex reactions is consistent with previous studies (Jackson et al., 1996; Tsai et al., 1994). The sensitivity and reliability of the MPN–multiplex PCR protocol was tested by seeding samples with live cells of the four species V. campbellii, V. harveyi, V. owensii and V. rotiferianus in equal proportions.

  • VIRAL LABORATORY DIAGNOSIS

    2009, Feigin and Cherry's Textbook of Pediatric Infectious Diseases, Sixth Edition
  • Adenovirus vaccine

    2008, Vaccines
View all citing articles on Scopus
View full text