The value of serial doppler imaging in central retinal vein occlusion: Correlation with visual recovery

https://doi.org/10.1016/S0009-9260(96)80159-0Get rights and content

A prospective study of 80 patients with central retinal vein occlusion (CRVO) was performed to determine whether Doppler flow measurements can predict visual outcome. All patients at presentation, had full ophthalmological examination, fluorescein angiography, relative afferent pupillary defect test and electroretinography to distinguish between ischaemic and non-ischaemic occlusions. In addition, all patients were examined at presentation with colour Doppler ultrasound using a 7.5 MHz linear array probe. Both the clinical examinations and colour Doppler ultrasound were repeated at one year following initial presentation in a smaller group of 20 patients.

A significant reduction in velocity within the central retinal vein was noted in the ischaemic compared with non-ischaemic CRVO affected eye at the time of the baseline scan. The minimum venous velocity within the central retinal vein was most severely affected. No velocity difference was present within the ophthalmic artery.

Follow-up at one year with colour Doppler ultrasound showed an increase in blood velocity values within the central retinal vein in the CRVO affected eye but this was of no prognostic value and did not correlate with clinical outcome. Serial colour Doppler ultrasound examinations, therefore, have no clinical application in patients with CRVO and are of no prognostic value.

References (22)

  • KohnerEM et al.

    Streptokinase in central retinal vein occlusion: a controlled clinical trial

    British Medical Journal

    (1976)
  • Cited by (20)

    • Seeing through thick and through thin: Retinal manifestations of thrombophilic and hyperviscosity syndromes

      2016, Survey of Ophthalmology
      Citation Excerpt :

      Furthermore, these tools will likely allow us to record responses of critical blood flow parameters in response to putative therapies for disease. In the past, serial color Doppler monitoring in CRVO has had limited clinical utility7; however, more recent developments in this technology reveal drastic reductions in retinal blood flow velocity in patients with retinal vein occlusion. Moreover, measurements made with this Doppler technology were predictive of visual prognosis.4,75

    • Doppler and Contrast Agents

      2011, Ophthalmic Ultrasonography: Expert Consult - Online and Print
    • Color Doppler Imaging of Retinal Diseases

      2010, Survey of Ophthalmology
      Citation Excerpt :

      A summary is presented in Table 2. The majority of case-control and cohort studies reported impairment of the blood flow parameters related to the ocular arterial circulation in patients with CRVO (8 reports5,7,8,64,65,89,123,124 of 12). Reduced blood velocity in the vein was found in all studies that measured velocity parameters in the central retinal vein in patients with CRVO.

    • Intracranial and orbital doppler in cerebrovascular disease

      2004, Seminars in Cerebrovascular Diseases and Stroke
    • Ischemic retinal vein occlusion: characterizing the more severe spectrum of retinal vein occlusion

      2018, Survey of Ophthalmology
      Citation Excerpt :

      It has been suggested that measures of blood flow are helpful in evaluating the severity of RVO and differentiating between iCRVO and non-iCRVO,17,18 although at present time, the usefulness of this technology to establish this differentiation remains controversial.20,26,296,309 Venous flow velocities were found to be significantly lower in iCRVO than in non-iCRVO.17,26,296 Tranquart et al reported that means of minimum and maximum venous flow velocities using color Doppler imaging were statistically significantly lower in iCRVO (n = 18) (mean 1.83 ± SD 0.94 and mean 2.94 ± SD 1.34 cm/s, respectively) than those in non-iCRVO (n = 50) (mean 2.28 ± SD 0.73 and mean 3.66 ± SD 1.19 cm/s, respectively).296

    View all citing articles on Scopus
    View full text