Corneal thickness and corneal endothelium in normotensive subjects with unilateral exfoliation syndrome

Graefes Arch Clin Exp Ophthalmol. 2000 Aug;238(8):659-63. doi: 10.1007/s004170000159.

Abstract

Purpose: To examine the central corneal thickness (CCT) and corneal endothelium in both eyes of patients with unilateral exfoliation syndrome (EXS). To determine the effect of CCT on the measurement of intraocular pressure (IOP).

Methods: In this cross-sectional clinical study, comparisons were made of CCT (Humphrey Ultrasonic Pachometer), corneal endothelial cells (Keeler-Konan contact specular microscope) and IOP (Goldmann applanation tonometer) between the exfoliative (E) and fellow nonexfoliative (NE) eyes in 40 normotensive patients with unilateral EXS. The CCT was used to obtain a corrected value for the IOP.

Results: The E eyes had significantly higher values for CCT (0.528+/-0.030 vs 0.523+/-0.032 mm, P<0.01) and IOP (15.7+/-3.6 vs 14.4+/-2.9 mmHg, P<0.001) than the fellow NE eyes. The paired E and NE eyes did not differ in endothelial cell density (2779+/-540 vs 2870+/-386 cells/mm2), in the coefficient of variation of cell size (0.25+/-0.03 vs 0.26+/-0.03) or in the frequency of hexagonal cells (80.5+/-6.5 vs 82.0+/-5.0%). After correcting IOP for CCT, the E eyes still had significantly higher IOP than the NE eyes (15.1+/-4.4 vs 14.2+/-3.7 mmHg, P<0.05).

Conclusion: Normotensive eyes with early EXS did not have quantitative (cell density) or qualitative (variation in cell size, frequency of hexagonal cells) morphological changes in corneal endothelium, but had higher values for IOP and CCT. After correcting IOP for CCT, the E eyes still had significantly higher IOP than the fellow NE eyes.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Cell Count
  • Cell Size
  • Cornea* / diagnostic imaging
  • Cornea* / ultrastructure
  • Cross-Sectional Studies
  • Endothelium, Corneal / diagnostic imaging
  • Endothelium, Corneal / ultrastructure
  • Exfoliation Syndrome / diagnosis*
  • Exfoliation Syndrome / physiopathology
  • Humans
  • Intraocular Pressure* / physiology
  • Middle Aged
  • Observer Variation
  • Tonometry, Ocular
  • Ultrasonography
  • Video Recording