Bimanual technique for insertion and positioning of endothelium-Descemet membrane graft in Descemet membrane endothelial keratoplasty

Cornea. 2013 Dec;32(12):1521-6. doi: 10.1097/ICO.0b013e3182933aee.

Abstract

Purpose: To describe a new bimanual technique for insertion and positioning of endothelium-Descemet membrane (EDM) grafts in Descemet membrane endothelial keratoplasty (DMEK).

Methods: Prospective, noncomparative, consecutive interventional case series, including 15 pseudophakic eyes of 15 patients treated with DMEK at the Instituto de Microcirugia Ocular, Barcelona, Spain. A bimanual infusion technique was used to introduce and position donor's EDM. Partial tamponade was achieved with 20% sulfur hexafluoride (SF6). Intraocular manipulation time of EDM grafts, rebubbling rate, and endothelial cell density were evaluated.

Results: Six months postoperatively, mean uncorrected visual acuity and best spectacle-corrected visual acuity (BSCVA) improved from 20/100 to 20/50 and from 20/80 to 20/25, respectively (P < 0.001). Six eyes (40%) had ≥ 20/20 BSCVA, and 13 (86%) eyes had ≥ 20/30 BSCVA. Mean donor cell density decreased from 2690 ± 302 to 1998 ± 621 cells per square millimeter, representing a mean cell loss of 26% ± 20%. EDM was stripped successfully in all cases. Mean intraocular manipulation time of donor's EDM (interval between main incision closure and final EDM positioning) was 4.10 ± 0.5 minutes. Intracameral air reinjection was needed in 1 case (6.6%) with a partial peripheral graft detachment. No episodes of immunologic graft rejection were documented.

Conclusions: Insertion and positioning of EDM grafts in DMEK was successfully achieved using this bimanual infusion technique and 20% SF6 partial tamponade, with a low intraocular manipulation time and very low postoperative rebubbling rates, regardless of the preservation method and the donor's age. However, prospective comparative studies are required to demonstrate the long-term safety compared with other approaches.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Corneal Diseases / physiopathology
  • Corneal Diseases / surgery*
  • Descemet Stripping Endothelial Keratoplasty / methods*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Visual Acuity / physiology