- Published on: 19 September 2019Reply to the letter of Dr. Tarannum Mansoori
We would like to thank Dr. Tarannum Mansoori for the interest in our study, “Intraocular pressure change after injection of intravitreal dexamethasone (Ozurdex) implant in Korean patients” and highlighting important issues about the intraocular pressure (IOP) measurement methods and the correlation of IOP with age.1
Show More
We used KT-800 Non-Contact Tonometer (Kowa, Tokyo, Japan) to measure IOP initially and rechecked with GAT if necessary. Unless the patient was diagnosed with glaucoma, NCT was initially used to measure both pre- and post-injection IOP.
As Dr. Tarannum Mansoori has pointed out, we also agree that GAT is the gold standard for IOP measurement. If the IOP measured with NCT was found to be high, it was always rechecked with GAT. GAT was used in 2 situations in our study. First, when the patients had a previous history of glaucoma, and second, when the patients’ IOP as measured with NCT was high (greater than 20). Thus, in cases of high IOP, the measurement involved NCT and was also always double checked with GAT. Moreover, multiple IOP measurements were obtained with GAT in cases of high IOP, and the average value of the measurements was regarded as the final IOP.
The range of age of the patients for injection of intravitreal dexamethasone was broad, from 16 to 88 years. We know that very young age (less than six years) or an older age are risk factors for steroid-induced glaucoma.2 However, regrettably, we have not performed any further analysis...Conflict of Interest:
None declared. - Published on: 19 September 2019Intraocular pressure change after injection of intravitreal dexamethasone (Ozurdex) implant
I read with interest and appreciate the article by Choi et al 1 on 'Intraocular pressure change after injection of intravitreal dexamethasone (Ozurdex) implant in Korean patients'.
As the study looks at the IOP changes after intravitreal dexamethasone implant, how the IOP was recorded for the patients is very important. The authors have reported that the intraocular pressure (IOP) was measured by non-contact tonometer (NCT) or Goldmann applanation tonometry (GAT) in this study. First, it is not mentioned as to which NCT was used for IOP measurement. If NCT was used to measure pre-injection IOP, was it used to measure post-injection IOP measurement also? Or on different visits IOP recording was done with NCT or GAT, is not clear. As GAT is still considered as a gold standard for IOP measurement, if IOP on NCT is found to be high, ideally it should be rechecked with GAT. Second, it is not mentioned whether a single IOP measurement was taken or multiple IOP measurements were obtained, taking the average value as the final IOP. Third, a s the lower range of age was 16 years (Table 1), was there any correlation of IOP change after the injection with the age?Reference
1. Choi W, Park SE, Kang HG et al. Intraocular pressure change after injection of intravitreal dexamethasone (Ozurdex) implant in Korean patients. Br J Ophthalmol 2018. Epub ahead
of print. doi:10.1136/ bjophthalmol-2018-312958Conflict of Interest: