Article Text

Download PDFPDF
Volumetric parameters-based differentiation of narrow angle from open angle and classification of angle configurations: an SS-OCT study

Abstract

Background To evaluate the diagnostic ability of volumetric parameters to differentiate narrow angle from open angle and distinguish different configurations of narrow angle.

Methods The current study was composed of two parts. In the first part, with gonioscopy as reference standard, we tested power of each parameter to differentiate narrow angle from open angle. In the second part, we evaluated the efficacy of different parameters to distinguish angle configurations which were subclassified into type 1 (pupillary block) and type 2 (non-pupillary block and multiple mechanisms) based on ultrasound biomicroscopy (UBM) images.

Results In part 1, the training set was composed of 117 narrow-angle eyes and 60 open-angle eyes, and the validation set included 38 narrow-angle eyes and 37 open-angle eyes. Anterior chamber volume (ACV) outperformed all the other parameters with an area under the curve (AUC) of 0.988. The sensitivity and specificity of the cut-off value 98.1 mm3 in the validation set were 90.0% and 97.1%, respectively. In part 2, training set was composed of 96 eyes of 88 patients with primary angle-closure disease, with 49 diagnosed as type 1 and 47 as type 2 configuration. 32 eyes were used for validation. A model comprised of iris volume (IV), iris thickness (IT) 2000 µm from the scleral spur and angle open distance (AOD) 750 µm from the scleral spur was found to have an AUC of 0.793 (95% CI, 0.695 to 0.870). Sensitivity and specificity of the model were 82.6% and 77.8% respectively in the validation set.

Conclusions With ACV, we can detect patients with narrow angle from open angle faster and more easily than AOD and anterior chamber depth. Then, for patients with narrow angle, the combination of IV, IT and AOD750 measured by swept-source optical coherence tomography could further classify configurations of angle closure compared with UBM.

  • glaucoma
  • anterior chamber
  • swept-source OCT

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Linked Articles

  • At a glance
    Keith Barton Jost B Jonas James Chodosh