Article Text

Download PDFPDF
Non-ophthalmologist screening for retinopathy of prematurity

Abstract

AIM To determine if a non-ophthalmologist can accurately screen for retinopathy of prematurity (ROP) by evaluating the posterior pole blood vessels of the retina. ROP is a common ocular disorder of premature infants and may require multiple screening examinations by an ophthalmologist to allow for timely intervention. Since there is a strong correlation between posterior pole vascular abnormalities and vision threatening ROP, screening examinations performed by non-ophthalmologist may yield useful clinical information in high risk infants.

METHODS Infants born at the Medical University of South Carolina who met screening criteria (n = 142) were examined by a single non-ophthalmologist using a direct ophthalmoscope to evaluate the posterior pole blood vessels for abnormalities of the venules and/or arterioles. To determine the accuracy of the non-ophthalmologist's clinical observations, infants were also examined by an ophthalmologist, using an indirect ophthalmoscope, who graded the posterior pole vessels as normal, dilated venules, or dilated and tortuous venules and arterioles (including “plus disease”).

RESULTS There was significant correlation (p <0.001) between the non-ophthalmologist's and ophthalmologist's diagnoses of posterior pole vascular abnormalities. 47 infants had normal posterior pole blood vessels by the non-ophthalmologist examination. Of these, 31 (66%) were considered to have normal vessels and 16 (34%) to have dilated venules by the ophthalmologist. The non-ophthalmologist correctly identified abnormal posterior pole vessels in all 21 infants diagnosed with abnormal arterioles and venules by the ophthalmologist. No infants with clinically important ROP (“prethreshold” or worse) would have failed detection by this screening method.

CONCLUSION Using a direct ophthalmoscope, a non-ophthalmologist can screen premature infants at risk for ROP by evaluating the posterior pole blood vessels of the retina. While not necessarily recommended for routine clinical practice, this technique may nevertheless be of value to those situations where ophthalmological consultation is unavailable or difficult to obtain.

  • prematurity
  • retinopathy of prematurity
  • screening protocols

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.