Article Text

Download PDFPDF
Does visual restitution training change absolute homonymous visual field defects? A fundus controlled study
  1. J Reinhard1,
  2. A Schreiber1,
  3. U Schiefer1,
  4. E. Kasten2,
  5. B A Sabel2,
  6. S Kenkel2,
  7. R Vonthein3 and
  8. S Trauzettel-Klosinski1
  1. 1University Eye Hospital, Department of Pathophysiology of Vision and Neuro-Ophthalmology, Tübingen, Germany
  2. 2Institute of Medical Psychology, University of Magdeburg, Germany
  3. 3Department of Medical Biometry, University of Tübingen, Germany
  1. Correspondence to: Jens Reinhard MD MSc University Eye Hospital, Schleichstrasse 12–16, 72076 Tübingen, Germany; jens.reinhardmed.uni-tuebingen.de

Abstract

Aim: To examine whether visual restitution training (VRT) is able to change absolute homonymous field defect, assessed with fundus controlled microperimetry, in patients with hemianopia.

Methods: 17 patients with stable homonymous visual field defects before and after a 6 month VRT period were investigated with a specialised microperimetric method using a scanning laser ophthalmoscope (SLO). Fixation was controlled by SLO fundus monitoring. The size of the field defect was quantified by calculating the ratio of the number of absolute defects and the number of test points; the training effect E was defined as the difference between these two ratios before and after training. A shift of the entire vertical visual field border by 1° would result in an E value of 0.14.

Results: The mean training effect of all right eyes was E = 0.025 (SD 0.052) and all left eyes E = 0.008 (SD 0.034). In one eye, a slight non-homonymous improvement along the horizontal meridian occurred.

Conclusions: In one patient, a slight improvement along the horizontal meridian was found in one eye. In none of the patients was an explicit homonymous change of the absolute field defect border observed after training.

  • HRP, high resolution perimetry
  • SLO, scanning laser ophthalmoscope
  • wpm, words per minute
  • VRT, visual restitution training
  • hemianopia
  • training
  • scanning laser ophthalmoscope
  • visual restoration therapy
  • 270
  • 263
  • HRP, high resolution perimetry
  • SLO, scanning laser ophthalmoscope
  • wpm, words per minute
  • VRT, visual restitution training
  • hemianopia
  • training
  • scanning laser ophthalmoscope
  • visual restoration therapy
  • 270
  • 263

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Notes

Linked Articles