Abstract

Aim: To evaluate if functionally relevant deficits in reading performance exist in children with essential microstrabismic amblyopia by comparing the monocular and binocular reading performance with the reading performance of normal sighted children with full visual acuity in both eyes.

Methods: The reading performance of 40 children (mean age 11.6 (SD 1.4) years) was evaluated monocularly and binocularly in randomised order, using standardised reading charts for the simultaneous determination of reading acuity and speed. 20 of the tested children were under treatment for unilateral microstrabismic amblyopia (visual acuity in the amblyopic eyes: logMAR 0.19 (0.15); fellow eyes −0.1 (0.07)); the others were normal sighted controls (visual acuity in the right eyes −0.04 (0.15); left eyes −0.08 (0.07)).

Results: In respect of the binocular maximum reading speed (MRS), significant differences were found between the children with microstrabismic amblyopia and the normal controls (p = 0.03): whereas the controls achieved a binocular MRS of 200.4 (11) wpm (words per minute), the children with unilateral amblyopia achieved only a binocular MRS of 172.9 (43.9) wpm. No significant differences between the two groups were found in respect of the binocular logMAR visual acuity and reading acuity (p>0.05). For the monocular reading performance, significant impairment was found in the amblyopic eyes, whereas no significant differences were found between the sound fellow eyes of the amblyopic children and the control group.

Conclusion: In binocular MRS, significant differences could be found between children with microstrabismic amblyopia and normal controls. This result indicates the presence of a functionally relevant reading impairment, even though the binocular visual acuity and reading acuity were both comparable with the control group.

  • CPS, critical print size
  • logRAD, logarithm of the reading acuity determination
  • MRS, maximum reading speed
  • RR charts, Radner reading charts
  • wpm, words per minute
  • amblyopia
  • microstrabismus
  • reading performance
  • reading speed
  • CPS, critical print size
  • logRAD, logarithm of the reading acuity determination
  • MRS, maximum reading speed
  • RR charts, Radner reading charts
  • wpm, words per minute
  • amblyopia
  • microstrabismus
  • reading performance
  • reading speed

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Supported by the “Jubiläumsfonds der österreichischen Nationalbank.”

  • Competing interests: none declared