Article Text

Download PDFPDF
Baseline IOP predicts selective laser trabeculoplasty success at 1 year post-treatment: results from a randomised clinical trial
  1. W G Hodge,
  2. K F Damji,
  3. W Rock,
  4. R Buhrmann,
  5. A M Bovell,
  6. Y Pan
  1. Department of Ophthalmology, The University of Ottawa Eye Institute, 501 Smyth Road, Ottawa, Ontario, K1H 8L6 Canada
  1. Correspondence to: Dr William G Hodge The University of Ottawa Eye Institute, 501 Smyth Road, Ottawa, ON K1H 8L6 Canada; whodgeottawahospital.on.ca

Abstract

Background/aims: The efficacy and safety of selective laser trabeculoplasty (SLT) has been found to be equivalent to argon laser trabeculoplasty (ALT). Since SLT produces significantly less disturbance to the trabecular meshwork and is theoretically more repeatable than ALT, it has potential to replace ALT as the standard procedure to treat medically uncontrolled open angle glaucoma. This study’s objective is to determine factors that predict successful SLT at 1 year post-treatment.

Methods: As part of a randomised clinical trial comparing the efficacy and safety of SLT to ALT, data on 72 SLT patients were collected, and successful SLT defined as having an SLT induced intraocular pressure (IOP) reduction of ⩾20% at 1 year post-treatment follow up.

Results: 43 out of the 72 patients who had completed their 1 year follow up visit had an IOP reduction of ⩾20% from baseline. No glaucoma risk factors studied predicted successful SLT. The amount of trabecular meshwork pigmentation was not a significant predictor. However, it was discovered that baseline IOP strongly predicted SLT success (odds ratio = 1.16; p = 0.0001).

Conclusion: SLT success was significantly predicted by baseline IOP but not by age, sex, other glaucoma risk factors, type of open angle glaucoma, or by degree of trabecular meshwork pigmentation.

  • ALT, argon laser trabeculoplasty
  • BCVA, best corrected visual acuity
  • IOP, intraocular pressure
  • PI, peripheral laser iridotomy
  • SLT, selective laser trabeculoplasty
  • TM, trabecular meshwork
  • selective laser trabeculoplasty
  • intraocular pressure
  • predictors
  • glaucoma risk factors
  • ALT, argon laser trabeculoplasty
  • BCVA, best corrected visual acuity
  • IOP, intraocular pressure
  • PI, peripheral laser iridotomy
  • SLT, selective laser trabeculoplasty
  • TM, trabecular meshwork
  • selective laser trabeculoplasty
  • intraocular pressure
  • predictors
  • glaucoma risk factors

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes