Abstract

Minimally invasive glaucoma surgeries (MIGS) can improve the conventional, pressure-dependent outflow by bypassing or ablating the trabecular meshwork (TM), or creating alternative drainage routes into the suprachoroidal or subconjunctival space. They have a highly favourable risk profile compared to penetrating surgeries, and lower intraocular pressure with variable efficacy that may depend on the extent of outflow segments accessed. Since they are highly standardised procedures that use clear corneal incisions, they can elegantly be combined with cataract and refractive procedures to improve vision in the same session. There is a growing need for surgeons to become proficient in MIGS to address the increasing prevalence of glaucoma and cataracts in a well-informed, aging population. Techniques of visualisation and instrumentation in an anatomically highly confined space with semitransparent tissues are fundamentally different from other anterior segment surgeries, and present even experienced surgeons with a substantial learning curve. Here, we provide practical tips, and review techniques and outcomes of TM bypass and ablation MIGS.

  • Glaucoma
  • Treatment Surgery
  • Treatment Lasers
  • Angle

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Introduction

There are compelling needs for ophthalmic surgeons to become proficient in minimally invasive glaucoma surgeries (MIGS) to address the increasing lifespan and glaucoma prevalence.1 ,2 Fewer patients and physicians are willing to accept the significant risks of traditional glaucoma surgeries that occur even in the most experienced hands: leakage, endophthalmitis, hypotony, hardware erosion, damage to ocular tissues and other complications that are vision threatening occur with an additive probability of 77% of trabeculectomies and 58% of tubes.3 Since cataracts and refractive errors commonly coexist, and cataract removal can further lower intraocular pressure (IOP),4 normalise anterior segment anatomy,5 and reduce release of pseudoexfoliative material or pigment,6 it is useful to address them in the same session. Expedited recovery, absence of postoperative procedures and ability to avoid conjunctival scarring, hypotony7 and choroidal effusion are additional benefits.8 ,9

MIGS require skills fundamentally different from traditional glaucoma surgery and may present even experienced anterior segment surgeons with a significant learning curve. Excellent gonioscopy skills and access to a surgical microscope with outstanding optics, large tilt capabilities, and illumination with a high Kelvin colour temperature (eg, a xenon high-intensity-discharge light source) are crucial to properly visualise the lacy and often non-pigmented trabecular meshwork (TM). MIGS can be divided into procedures that improve pressure-dependent outflow by (1) bypassing or eliminating the TM, and ones that (2) create alternative drainage routes by shunting aqueous humour into the suprachoroidal or subconjunctival space. Here, we review techniques and results of TM bypass and ablation surgeries and share key steps from our own experience in making them more successful. The sections are ordered by the extent of access to outflow segments, reflecting recent insights from canalography into how discontinuous and septated Schlemm's canal (SC) is in vivo.10 ,11

TM bypass devices

iStent Inject

Concept and technique

The second-generation iStent Inject (Glaukos, Laguna Hills, California, USA), is 0.4 mm long, 0.3 mm wide and consists of titanium with heparin coating. Two bullet-shaped stents are preloaded in an injector. This allows for perpendicular implantation into TM and penetration of the tip into SC of both stents without withdrawing the inserter, avoiding hypotony and reflux of blood from the collector channels and SC.12 TM stents increase outflow by allowing aqueous to directly bypass the TM. Since SC is discontinuous and septated, flow is not circumferential10 ,11; outflow segments may be accessed over approximately 60° with a single stent although individual anatomy varies.13 Placement of a second stent may increase the number of drainage segments accessed and potentially lower IOP further.

The preoperative regimen is identical to standard phacoemulsification.14 Following cataract extraction, intracameral acetylcholine is used for miosis. The chamber is deepened with viscoelastic. Overinflation must be avoided as it can collapse SC and lead to implantation of the device into the outer wall of SC instead of the TM, while insufficient viscoelastic prevents proper angle visualisation. After rotating the microscope the first stent is inserted with a gentle push into nasal TM under direct gonioscopic view and released from the inserter. The second stent is then placed in a position of at least two clock hours away from the first one (to increase the chance of accessing a different drainage segment). Viscoelastic and refluxing blood are aspirated, and the stent placement is confirmed gonioscopically. The eye is pressurised with saline. A fluoroquinolone is given four times per day for 1 week, along with prednisolone acetate 1%, 4–6 times a day, and tapered weekly as for all procedures discussed here.

Results

Outflow facility doubled after inserting one stent and doubled again with two stents in an anterior chamber (AC) perfusion model.12 Twenty patients in a consecutive series had a mean IOP of 20 mm Hg on 1.3 medications which was reduced to 17 mm Hg (14% decrease) on 0.3 drops 1 year after combined phacoemulsification and two stent placements.15 Side effects included transient IOP spikes >30 mm Hg at postoperative day 1 in 15%. With four patients, although two stents were thought to have been inserted, only one could be found. No patient lost vision (figure 1).

Figure 1

Procedures enhancing conventional outflow by degree of angle access. Left half: trabecular meshwork (TM) bypass stents (counter clockwise): (a) iStent inject, (b) iStent G1 and (c) hydrus. Right half: TM ablation devices (clockwise): (d) laser-assisted endoscopic goniopuncture with single, circular entry and (e) trabectome with plasma ablation tip that can remove TM up to 180° (blue half-circle arrows). The naturally segmented and discontinuous Schlemm's canal limits the extent of access to drainage segments that can be achieved with bypass stents (background canalography image courtesy of The Glaucoma Imaging Group, UPMC Eye Center, University of Pittsburgh School of Medicine).

iStent G1

Concept and technique

The first generation iStent G1 (Glaukos) is three times larger than the iStent Inject. After angle visualisation described above, this device is gently leaned against the TM but slightly left towards the opposite side of the chamber to provide a more pointed engagement for easier entry (figure 2). Using a gentle sweeping motion, the stent is pushed through the TM while the base is kept parallel to the iris.16 The stent is released and gently tapped with a leftward motion to properly insert it and drive it through the TM or free it from the outer wall.

Figure 2

Engaging the trabecular meshwork with the iStent G1 and trabectome. A more pointed angle (left inset) allows for easier entry into Schlemm's canal (blue) compared to a parallel orientation (right inset).

Results

One stent doubled the outflow facility in perfused donor eyes and insertion of two stents quadrupled it.17 An in vivo analysis used fluorophotometry to confirm that the placement of two stents with phacoemulsification increased trabecular outflow facility by 275% over baseline, while phacoemulsification alone increased it by only 46%.18 A prospective study showed that IOP decreased by 25% at 6 months, while the number of medications decreased from 1.5 to 1 (n=58).14 Only three cases (5%) were advanced to trabeculectomy. At 12 months, the IOP reduction averaged 18%, and 62% patients had an IOP ≤18 mm Hg, while 26% had ≤15 mm Hg.14 In a randomised controlled trial (RCT) that compared 36 patients who underwent stand-alone phacoemulsification to a combined group of phacoemulsification/stent placement, there was a a 17% IOP decrease at 15 months in the combined group versus a 9% decrease in the stand-alone phacoemulsification group despite being on one more medication.19 Another RCT (n=240) required an entry IOP of ≥22 mm Hg following medication washout.20 Per protocol, postoperative IOP was maintained below 21 with topical medications in both groups, and mean reduction of IOP was only 1.5 mm Hg in the treatment group versus 1 mm Hg in the control group. After 24 months, the IOP decrease was 8% in the combined group versus 1% in the phacoemulsification group.21

A 5-year study of 13 combined phacoemulsification and stent procedures found a 16% decrease from 19 mm Hg baseline, while 42% of patients required no further medication.22 A study that compared two with three stents (combined with phacoemulsification) found a 20% pressure reduction in both groups after 1 year.23 However, only 46% of the patients with two stents were off medication at 1 year versus 72% with three stents. A study of stand-alone stent implantation (n=10) found a 27% IOP decrease after 1 year and mean reduction of medications from 2.9 to 1.8.24

Complications unique to the iStent include obstruction by fibrin or peripheral anterior synechiae (PAS) (4% of 111 patients20) and stent malposition (14%). Stent obstruction has been managed with observation or argon laser. Four of 111 patients required surgical stent repositioning or replacement. Although increased IOP following stent placement has been reported, it occurred more frequently in the control group with cataract surgery alone.21 No patient lost more than one line of Snellen visual acuity. There are no reports of serious complications, such as choroidal effusion, persistent hypotony, bleb formation, or endophthalmitis.

Hydrus: ab interno SC scaffold

Concept and technique

The hydrus microstent scaffold (Ivantis, Irvine, California, USA), is composed of nitinol, a nickel-titanium alloy with a 1 mm terminal lumen in the AC. This device dilates SC to a diameter of 241 microns, reducing flow resistance and bypassing TM, and extends the range of circumferential flow by disrupting smaller septations.25 There is a 15 mm long version and an 8 mm flatter version.26 The 15 mm stent dilates about five clock hours of SC and doubled the outflow facility; both devices increase outflow facility to a similar extent.26 ,27

The hydrus is preloaded in an injector with a bent tip for gonioscopic insertion into the nasal SC. The hydrus is advanced to engage the TM and advanced into the SC. Blood can be seen refluxing from the tip in the AC after implantation.

Results

Preliminary data on 28 patients showed that after 6 months, combined phacoemulsification and stent insertion resulted in approximately a 15% decrease in IOP from a baseline of 18 mm Hg, while medications decreased from 2.4 to 0.1.28 Another preliminary study found an approximately 35% decrease in IOP from 25 mm Hg (measured after medication washout) at 12 months.29 The two most common complications were transient hyphema in 15% and PAS formation in 10% of patients.

TM ablation devices

Laser-assisted endoscopic trabeculostomy and goniopuncture

Concept and technique

Laser-assisted endoscopic trabeculostomy removes TM over a circular area and was first demonstrated with a ruby laser,30 followed by argon,31 neodymium-doped:YAG,32–34 erbium:YAG35 ,36 and excimer laser.37 Dietlein et al38 recognised that sufficiently large ablation could only be achieved with end-firing endo-probes with 200–320 micron diameter and 4–6 mJ energy. Using an erbium:YAG laser (Sklerotom 2.9, Endognost; Schwind) at a wavelength of 2.94 microns, perforations are 300 microns.39 A study on cadaver eyes confirmed that there was little thermal damage, and the outflow more than doubled40 after 18 pulses of 16 mJ to the nasal TM. Endoscopic excimer laser trabeculostomy (ELT, AIDA, TUI-Laser, Munich, Germany)41 ,42 involves a 308 nm wavelength ablation over a 500-micron area.43 The instrument tip is inserted across the AC and guided gonioscopically to the TM. Successful application causes TM blanching and bubbles. As with other angle surgeries, successful penetration into SC produces blood reflux when IOP is below episcleral venous pressure.

Results

A prospective study (n=59) using the erbium:YAG laser demonstrated a 30% decrease in IOP from a baseline of 23 mm Hg on one less medication at 1 year;44 71% of patients achieved a 20% decrease in IOP. Fibrin reaction necessitating surgery occurred in 5%. When retrospectively compared to a group of 17 patients who underwent combined phacoemulsification with trabeculectomy ab externo,45 the laser group demonstrated a 34% IOP decrease versus 29% in the trabeculectomy group at 3 years, although the trabeculectomy group was on significantly fewer medications.

Similarly, after eight excimer applications resulted in a 32% IOP decrease from a baseline of 25 mm Hg at 2 years with 1.5 fewer medications (n=21). A larger study (n=75) showed a 30% decrease from a baseline of 24 mm Hg after 1 year, although the number of medications did not decrease.41 Only 46% of patients maintained a 20% IOP decrease to less than 21 mm Hg. When ELT was compared to 180° selective laser trabeculoplasty (SLT) in an RCT,42 treatments lowered the IOP by 30% and 21%, respectively, with a similar survival time. There was an IOP spike on postoperative day 1 in 20% of the ELT group versus 13% in the SLT group. No vision-threatening complications were reported. A recent 1-year-study found that patients with a baseline IOP≤21 (mean 16.5 mm Hg) showed a mean IOP decrease of 12% with 1.1 less medications compared to a decrease of 37% on 0.6 less medications in patients with a baseline IOP above 21 (mean 25.8 mm Hg).46 Long-term failure is typically caused by migration of immediately adjacent47 or remote cell types.48 A concern is that light scatter with a wavelength of 308 nm can be mutagenic.49

Trabeculectomy ab interno with the trabectome

Concept and technique

Ab interno trabeculectomy with the trabectome (AIT, Neomedix, Tustin, California, USA) is a plasma surgery ablation technique that uses a bipolar 550 kHz electrode tip to remove the primary resistance to outflow, the TM.50 ,51 Because the mechanism is not cautery but ionisation and disintegration, heat dissipation is highly confined: histology showed no thermal damage to adjacent tissues or outer wall, although margins of the immediate ablation area did occasionally show coagulation effects.52 TM can be ablated over 180°, providing access to many more drainage segments compared with bypass stents, increasing chance of success and lower IOPs, thereby broadening indication criteria to advanced glaucomas, acute and chronic angle closure, or inactive neovascular glaucoma. Between 5 and 6 collector orifices may be exposed per millimetre of SC (figure 2), which may have lower flow speeds and a lower risk to aspirate iris compared to the single intake of stents.

Through a paracentesis, the eye is well pressurised with intracameral lidocaine, and a 1.6 mm iris-parallel, uni-planar main incision is created 2 mm anterior to the limbus to prevent iris prolapse. The inner third is flared to improve mobility and eliminate striae from torque. Hypotony is induced to allow reflux of blood into SC highlighting the intended ablation site. The irrigation bottle is raised high on continuous irrigation. No viscoelastic is used so to avoid optical interfaces and trapping of ablation bubbles. After insertion of the trabectome, the TM is engaged (figures 2 and 3) with the tip at a 45° upward angle at the level of the scleral spur (figure 4), and the SC is entered with an upward, then left movement. The footplate of the trabectome tip appears obscured by the lacy TM when properly inserted. The TM should feed into the space between the footplate and electrode tips and not push up against the leading, golden electrode. Any outward push against the outer wall must be strictly avoided so as not to damage collector intakes. Excessive energy above 1 mW can cause coagulation necrosis during ablation, which is seen as blackening along the ablation lips, and may incite wound healing with progressive failure. The first 60° are ablated continuously and should never be forceful. In a successful ablation, the outer wall of SC will appear white. During the remaining 30°, the gonioscopy lens is rotated into the direction of ablation, the wrist increasingly supinated and range of view increased by floating the heel of the goniolens (figure 5). The tip is then disengaged, rotated 180° pointing downward by rolling it between the thumb, index and middle finger and progressively pronating the wrist. The TM is engaged at the original starting point and ablation proceeds into the opposite direction. Removal of the trabectome from the eye midway results in hyphema and so should be avoided. At conclusion, a small amount of viscoelastic can be retained to protect against hyphema from hypotony.53–55 In addition to the postoperative drops described above, 1% pilocarpine is used four times a day for 1 month, and three times per day for another month to keep the iris flat and away from the angle.56 Since most flow occurs where the TM was removed57 a significant pressure-lowering effect from pilocarpine-mediated tension on the scleral spur and TM is not seen.58

Figure 3

Trabectome. (A) Schematic of trabectome ablating trabecular meshwork (TM), opening a view to the white inner wall of Schlemm's canal (courtesy of Neomedix Corp., Tustin, California, USA) and (B) scanning electron microscopy of Schlemm's canal following successful TM ablation with a collector channel seen clearly at far right (courtesy of Douglas H Johnson for Neomedix).

Figure 4

Atraumatic entry into Schlemm's canal can be most easily achieved by angling the tip 45° upward, directly anterior to the scleral spur, to avoid collapse of the canal during engagement. The tip is then moved up, in and along Schlemm's canal (dotted line).

Figure 5

Gonioscopic view and hand position in angle surgery (trabectome shown). After engagement and Schlemm's canal entry at the nasal trabecular meshwork slightly off to the left, ablation is continued for 90° while the lens is rotated in the same direction and the eye (right eye shown) is tilted towards the brow. The same is repeated for the opposite direction. Gonioscopic prism power is increased by lifting the lens off the cornea to float in saline at the final clock hours.

Results

Over nearly one decade, more than 50 000 AIT cases with adult and infantile glaucoma have been documented. More than 5000 were recorded in detail and followed long-term via a repository that includes the submitted first cases of new surgeons and is available to researchers.59 In the largest study of 1878 cases, some patients who had been followed for 6 years are still maintaining a 38% IOP reduction.60 In a retrospective study (n=1127) with 5 years follow-up, the definition of failure was similar to that of the Tube Versus Trabeculectomy study,61 with failure being defined as any one of: final IOP above 21 mm Hg, less than a 20% decrease from baseline IOP, or further surgery.62 Using this definition, the failure rate after 4 years was approximately 53%. Risk factors for failure are lower baseline IOP63 and younger age.64

We analysed our own outcomes of 192 consecutive combined AIT and cataract surgeries65 in a retrospective study approved by the institutional review board. The 180° ablation technique above was applied to all patients consisting of 65% primary open-angle, 10% low-pressure, 7% pseudoexfoliation, and 4% angle-closure glaucoma. The IOP decreased from 20.1±8.2 mm Hg to 14.5±4.5 mm Hg (28% decrease, p<0.05). Of the patients who had 2 years of follow-up, the IOP decrease was maintained at a 23% decrease (p<0.05), although the number of topical medications had then increased by an average of 0.5. After 1 year, 81% of patients had an IOP≤18, while 52% of patients had an IOP≤15, and 27% had an IOP≤12 (p<0.05). Best corrected mean visual acuity improved from 20/50 at baseline to 20/32 (p<0.05). One patient needed further surgery (aqueous shunt) and three were managed with additional laser procedures (2 selective laser trabeculoplasties and 1 cyclophotocoagulation).

A common postoperative observation is reflux of blood from the collector channels indicating free communication with the drainage system,64 but only one case needing a surgical intervention for hyphema has been reported.66 PAS may occur in 24%67 and can be lysed with photocoagulation or with the Nd:YAG laser.56 Transient postoperative IOP elevations of more than 10 mm Hg occur in 4–10%68 ,69 of patients consistent with other MIGS. Other complications reported in less than 1% include cyclodialysis cleft,64 transient hypotony, lens injury, aqueous misdirection60 and choroidal haemorrhage.60

Surgical comparisons

There has been no published study directly comparing these MIGS to each other, and the studies discussed have different patient populations and indications for surgery. From the available data, laser trabeculostomy was reported to lower the IOP by 30%,41 ,42 compared to the single published paper on the second-generation iStent with a 14% IOP decrease with two stents.15 The overall mean reported IOP reduction for the first-generation iStent was near 20%14 ,22 ,70 and 25% for AIT with phacoemulsification,69 ,71 and 35% without phacoemulsification.59 ,62 ,69 The mechanism of MIGS procedures discussed here cannot be expected to produce IOP reductions that can be expressed as a simple percentage of preoperative IOP as may be the case with topical medications. Rather, postoperative IOP will be determined by outflow resistance that is downstream of the TM and independent of preoperative IOP. As a result, a patient with high preoperative IOP will typically have a postoperative pressure similar to someone with relatively low preoperative IOP. Increasing the extent of TM bypass (hydrus) or removal (trabectome) to access more outflow segments,13 may improve surgical success rates and possibly also reduce IOP more effectively, while the reverse is seen for the incidence of transient, postoperative hyphema. All these procedures are highly standardised and faster than traditional glaucoma surgery.

Conclusions

With an improved risk profile, MIGS offer the ability to intervene earlier, to lower IOP efficiently and improve vision function in the same session, thereby reducing noncompliance and costs.72 Procedures are highly standardised and faster than traditional glaucoma surgery. It is likely that the amount of IOP reduction is related to the extent of access to outflow segments while the reverse has been reported for the amount of transient, postoperative hyphema. To prevent stents from blocking (figure 6) or missing prominent collector channels and drainage segments, it would be desirable to assess the intended location by canalography.11 Procedures discussed here require a sufficiently working conventional outflow system downstream of the TM. Still, preclinical MIGS may be able to use alternative outflow pathways that could be used to bypass it if MIGS described here fail.73 ,74 Key steps in all MIGS are: properly identifying SC; avoiding undue outward pressure; confirming proper placement of devices or ablation instruments. Since techniques and visualisation are considerably different from traditional glaucoma and cataract surgery, surgeons beginning MIGS should be prepared for a significant learning curve.

Figure 6

Challenges encountered by microstents. (A) Section through microstent in Schlemm's canal (SC) shows that the lumen can become partially occluded. (B) Scaffold device that distends SC effectively but may compress adjacent collector channels (CC; courtesy of Ivantis Inc., Irvine, California, USA).

References

Footnotes

  • Contributors KK contributed to conception and design, or analysis and interpretation of data, drafting the article and revising it critically for important intellectual content and to final approval of the version to be published. JS contributed to conception and design, or analysis and interpretation of data, drafting the article and revising it critically for important intellectual content and to final approval of the version to be published. NL contributed to conception and design, or analysis and interpretation of data, drafting the article and revising it critically for important intellectual content and to final approval of the version to be published.

  • Funding This work was supported, in part, by the National Institute of Health grant number R01EY013178 and K08EY022737, and an unrestricted grant from Research to Prevent Blindness.

  • Competing interests NL is a trabectome wet lab trainer for Neomedix Inc.

  • Ethics approval Yale University.

  • Provenance and peer review Not commissioned; externally peer reviewed.