Article Text

Download PDFPDF
Assessment of choroidal thickness before and after steep Trendelenburg position using swept-source optical coherence tomography
  1. Tyler Hyungtaek Rim1,
  2. Christopher Seungkyu Lee1,
  3. Kangyoon Kim1,
  4. Sung Soo Kim1,2
  1. 1Department of Ophthalmology, Severance Hospital, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea
  2. 2Yonsei Healthcare Big Data-Based Knowledge Integration System Research Center and Institute of Convergence Science, Yonsei University College of Medicine, Seoul, Korea
  1. Correspondence to Professor Sung Soo Kim, Department of Ophthalmology, Severance Hospital, Institute of Vision Research, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul 120-752, Korea; semekim{at}yuhs.ac

Abstract

Background To evaluate changes in choroidal thickness before and after steep Trendelenburg position (STP, 40° head-down) using automated segmentation software to analyse swept-source optical coherence tomography (SS-OCT) data.

Methods The eyes of 20 healthy volunteers underwent a three-dimensional wide scanning protocol with SS-OCT (Topcon, Tokyo, Japan) at baseline, immediately after STP was initiated, and 5, 10 and 15 min after STP; blood pressure and heart rate were measured concurrently. The predictive mean difference was calculated using a generalised linear mixed model that adjusted for potential confounders.

Results Mean choroidal thickness significantly and transiently increased immediately (268.18±9.24 μm, p<0.01) and 5 min (264.25±9.30 μm, p=0.03) after STP, relative to baseline (256.51±9.20 μm). However, choroidal thickness decreased by 10 min (262.51±9.34 μm, p=0.15) and 15 min (261.38±9.40 μm, p=0.37) after STP. Mean arterial pressure also transiently increased from baseline (78.2±1.2 mm Hg) immediately after STP (79.9±1.1 mm Hg, p=0.01), but normalised by 5 min after STP (p>0.05 for all comparisons ≥5 min).

Conclusions Choroidal thickness significantly but transiently increases after adopting STP, as evaluated by automated layer segmentation analysis of SS-OCT data.

  • Anatomy
  • Choroid
  • Imaging

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Linked Articles

  • At a glance
    Keith Barton James Chodosh Jost Jonas