Article Text

Telemedicine for detecting diabetic retinopathy: a systematic review and meta-analysis
  1. Lili Shi1,2,
  2. Huiqun Wu1,
  3. Jiancheng Dong1,
  4. Kui Jiang1,
  5. Xiting Lu3,
  6. Jian Shi4
  1. 1Department of Medical informatics, Nantong University, Nantong, China
  2. 2Nantong University Library, Nantong, China
  3. 3Department of Ophthalmology, Suzhou Municipal Hospital, Suzhou, China
  4. 4Department of Ophthalmology, Affiliated Hospital of Nantong University, Nantong, China
  1. Correspondence to Professor Jiancheng Dong; dongjc{at}ntu.edu.cn

Abstract

Objective To determine the diagnostic accuracy of telemedicine in various clinical levels of diabetic retinopathy (DR) and diabetic macular oedema (DME).

Methods PubMed, EMBASE and Cochrane databases were searched for telemedicine and DR. The methodological quality of included studies was evaluated using the Quality Assessment for Diagnostic Accuracy Studies (QUADAS-2). Measures of sensitivity, specificity and other variables were pooled using a random effects model. Summary receiver operating characteristic curves were used to estimate overall test performance. Meta-regression and subgroup analyses were used to identify sources of heterogeneity. Publication bias was evaluated using Stata V.12.0.

Results Twenty articles involving 1960 participants were included. Pooled sensitivity of telemedicine exceeded 80% in detecting the absence of DR, low- or high-risk proliferative diabetic retinopathy (PDR), it exceeded 70% in detecting mild or moderate non-proliferative diabetic retinopathy (NPDR), DME and clinically significant macular oedema (CSME) and was 53% (95% CI 45% to 62%) in detecting severe NPDR. Pooled specificity of telemedicine exceeded 90%, except in the detection of mild NPDR which reached 89% (95% CI 88% to 91%). Diagnostic accuracy was higher with digital images obtained through mydriasis than through non-mydriasis, and was highest when a wide angle (100–200°) was used compared with a narrower angle (45–60°, 30° or 35°) in detecting the absence of DR and the presence of mild NPDR. No potential publication bias was detected.

Conclusions The diagnostic accuracy of telemedicine using digital imaging in DR is overall high. It can be used widely for DR screening. Telemedicine based on the digital imaging technique that combines mydriasis with a wide angle field (100–200°) is the best choice in detecting the absence of DR and the presence of mild NPDR.

  • Diagnostic tests/Investigation
  • Telemedicine
  • Retina

This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Supplementary materials

  • Supplementary Data

    This web only file has been produced by the BMJ Publishing Group from an electronic file supplied by the author(s) and has not been edited for content.

    Files in this Data Supplement:

Linked Articles

  • At a glance
    Keith Barton James Chodosh Jost Jonas