RT Journal Article SR Electronic T1 Outcome of graft free Molteno tube insertion JF British Journal of Ophthalmology JO Br J Ophthalmol FD BMJ Publishing Group Ltd. SP 501 OP 505 DO 10.1136/bjo.2005.079087 VO 90 IS 4 A1 J K Leong A1 P McCluskey A1 S Lightman A1 H M A Towler YR 2006 UL http://bjo.bmj.com/content/90/4/501.abstract AB Aims: To determine the long term outcome of Molteno implants inserted using a modified surgical technique that eliminates the need for a donor scleral graft. Methods: Retrospective case series involving a medical record analysis of 35 consecutive patients undergoing first Molteno implant surgery for refractory glaucoma. The main outcomes included life table analysis of intraocular pressure control following surgery and frequency of intraoperative and postoperative complications. Results: There were no complications related specifically to the modified method of tube placement. Medium term intraocular pressure control was similar to other series. Conclusions: This simplified method for the insertion of Molteno implants eliminates the need for a donor scleral graft while maintaining the implant’s ability to control intraocular pressure.