TY - JOUR T1 - Management of limbal stem cell deficiency by amnion-assisted conjunctival epithelial redirection using vacuum-dried amniotic membrane and fibrin glue JF - British Journal of Ophthalmology JO - Br J Ophthalmol DO - 10.1136/bjophthalmol-2020-318496 SP - bjophthalmol-2020-318496 AU - Harminder Singh Dua AU - Darren Shu Jeng Ting AU - Ahmed AlSaadi AU - Dalia G Said Y1 - 2021/10/05 UR - http://bjo.bmj.com/content/early/2021/10/04/bjophthalmol-2020-318496.abstract N2 - Purpose To study the outcome of a modified amnion-assisted conjunctival epithelial redirection (ACER) technique using vacuum-dried amnion (Omnigen) and fibrin glue for managing total limbal stem cell deficiency (LSCD).Method A retrospective, interventional case series of all patients with total LSCD who underwent limbal stem cell transplant (LSCT) using the modified ACER procedure between 2016 and 2019. The outcome was defined as: (1) success: complete corneal re-epithelialisation without conjunctivalisation; (2) partial success: sub-total corneal re-epithelialisation with partial non-progressive conjunctivalisation sparing the visual axis and (3) failure: conjunctivalisation affecting the visual axis.Results Ten patients (six men), with a mean age of 46.2±18.4 years, were included. The mean follow-up was 23.0±13.9 months. Causes of LSCD were chemical eye injury (30%), congenital aniridia-related keratopathy (30%), ocular surface malignancy (20%), Steven-Johnson syndrome (10%) and contact lens overuse (10%). 50% were bilateral. The time from diagnosis to ACER (for acquired causes) was 45.6±44.4 months. 80% of patients achieved a complete/partial success following ACER and 20% of patients required repeat LSCT. Auto-LSCT was associated with a significantly higher chance of success than allo-LSCT (p=0.048). The mean best-corrected-visual-acuity (logMAR) improved significantly from 1.76±0.64 preoperatively to 0.94±0.94 at final follow-up (p=0.009). Omnigen was available off-the-shelf stored at room temperature and its transparency enabled visualisation of the healing epithelium beneath.Conclusion LSCT using the modified ACER serves as an effective ocular surface reconstruction technique in managing total LSCD and improving vision. Vacuum-dried amnion provides advantages of easy handling, transparency and storage at room temperature.Data are available upon reasonable request. Individual patient data are stored in the hospital’s electronic system and can be retrieved on reasonable request. ER -