Table 1

 Efficiency of transduction of human corneal endothelium by AdV encoding eGFP

AdV dose (MOI)*Nopfu Adv per corneaDonor age† (years)Storage time†‡ (days)Endothelial cell density†§ (cells/mm2)% eGFP+ cells per cornea†§Transductionfailures¶
*MOI: multiplicity of infection; †Mean (SD); ‡Time in cold storage from enucleation until transduction; §As calculated from five central fields (0.15 mm2) on corneal flat mounts by fluorescence microscopy; ¶Transduction failures: fewer than 2% eGFP positive cells/cornea; **p<0.01 compared to very high dose group; ††p<0.05 compared to low and no dose groups.
None3071 (6)21 (7)1367 (952)0
Low (10)32×10672 (4)25 (3)2720 (611)**8 (3)1
Intermediate (25–100)85×106−2×10768 (10)17 (6)2195 (558)**54 (31)0
High (250–1500)135×107−3×10872 (19)16 (7)2163 (669)**78 (31)††1
Very high (10000)22×10965 (8)27 (2)98 (129)64 (26)0