Table 2

Comparisons of refractive outcomes between the SMILE and FS-LASIK groups

ParametersSMILE groupFS-LASIK groupP values
MeanSDMeanSD
LogMAR UDVA−0.050.08−0.020.090.069
Sphere (D)−0.030.50−0.160.690.306
Cylinder (D)−0.210.25−0.240.320.899
Spherical equivalent−0.140.49−0.280.650.317
LogMAR CDVA−0.110.07−0.080.080.058
Axis length (mm)26.051.0826.301.080.107
The efficacy index1.050.191.010.210.352
The safety index1.190.171.150.210.307
TIA0.940.631.010.870.992
SIA0.900.581.010.910.802
DV0.210.240.240.320.637
CI0.980.261.000.450.276
MofE0.040.230.010.240.711
AofE−0.291.370.161.480.148
IOS0.270.320.380.550.671
FI0.600.760.730.750.345
  • AofE, angle of error; CDVA, corrected distance visualacuity; CI, correction index; DV, difference vector; FI, flattening index; FS-LASIK,femtosecond laser-assisted laser in situ keratomileusis; IOS, index of success; MofE, magnitude of error; SIA,surgically induced astigmatism; SMILE, smallincision lenticule extraction; TIA, target-induced astigmatism; UDVA, uncorrected distance visual acuity.