Comparisons of the values of MD, PSD and pointwise sensitivities
variables | SITA-standard | VBLR-VF | P value* | P value** | P value† | P value†† | |
1st measurement | MD, (mean±SD) (range), dB | −7.9±6.2 (−26.7 to 0.6) | −8.2±6.4 (−25.6 to 1.4) | 0.99 | 0.99 | 0.96 | 0.99 |
2nd measurement | MD, (mean±SD) (range), dB | −8.7±6.2 (−27.3 to 0.3) | −8.0±6.2 (−24.9 to 1.6) | ||||
1st measurement | PSD, (mean±SD) (range), dB | 8.5±4.9 (1.1 to 16.0) | 8.7±4.8 (0.9 to 16.1) | 0.30 | 0.97 | 0.92 | 0.39 |
2nd measurement | PSD, (mean±SD) (range), dB | 8.6±4.8 (1.1 to 16.6) | 8.6±4.7 (0.9 to 16.2) | ||||
1st measurement | Pointwise sensitivity, (mean±SD) (range), dB | 21.8±11.2 (0 to 39) | 21.0±11.4 (0 to 41) | 1.00 | 0.64 | <0.001 | <0.001 |
2nd measurement | Pointwise sensitivity, (mean±SD) (range), dB | 21.0±11.2 (0 to 35) | 21.1±11.2 (0 to 40) |
*Shows the result of the comparison between SITA standard (1st) and SITA standard (2nd).
**Shows the result of the comparison between VBLR-VF (1st) and VBLR-VF (2nd).
†Shows the result of the comparison between SITA standard (1st) and VBLR-VF (1st).
††Shows the result of the comparison between SITA standard (2nd) and VBLR-VF (2nd).
MD, mean deviation; PSD, pattern SD; SITA, Swedish interactive threshold algorithm; VBLR, Variational Bayes Linear Regression; VF, visual field.