JHU | ||||
Modality | VA category | AUC | Precision | Recall |
Infrared only | Overall | 0.83 | 0.78 | 0.77 |
Snellen 20/40 or better | 0.71 | 0.83 | ||
Worse than Snellen 20/40 | 0.83 | 0.71 | ||
OCT only | Overall | 0.87 | 0.76 | 0.76 |
Snellen 20/40 or better | 0.73 | 0.75 | ||
Worse than Snellen 20/40 | 0.78 | 0.76 | ||
Combined | Overall | 0.85 | 0.83 | 0.82 |
Snellen 20/40 or better | 0.76 | 0.89 | ||
Worse than Snellen 20/40 | 0.89 | 0.76 | ||
AUMC | ||||
Modality | VA category | AUC | Precision | Recall |
Infrared only | Overall | 0.78 | 0.69 | 0.63 |
Snellen 20/40 or better | 0.80 | 0.40 | ||
Worse than Snellen 20/40 | 0.56 | 0.88 | ||
OCT only | Overall | 0.87 | 0.79 | 0.79 |
Snellen 20/40 or better | 0.84 | 0.74 | ||
Worse than Snellen 20/40 | 0.74 | 0.84 | ||
Combined | Overall | 0.85 | 0.77 | 0.77 |
Snellen 20/40 or better | 0.78 | 0.78 | ||
Worse than Snellen 20/40 | 0.75 | 0.75 |
Three versions of the network were trained and tested: infrared only, OCT only and combined image.
AUC, area under the curve; OCT, optical coherence tomography.; VA, visual acuity.