Article Text

Download PDFPDF
Referenced scans improve the repeatability of optical coherence tomography angiography measurements in normal and glaucoma eyes
  1. Harsha Laxmana Rao1,
  2. Srilakshmi Dasari1,
  3. Mohammed Riyazuddin1,
  4. Raghavan Lavanya1,
  5. Narenda K P1,
  6. Zia Sultan Pradhan1,
  7. Sasan Moghimi2,
  8. Kaweh Mansouri3,
  9. Carroll A B Webers4,
  10. Robert N Weinreb5
  1. 1 Narayana Nethralaya, Bangalore, India
  2. 2 Farabi Eye Hospital, Tehran, Iran (the Islamic Republic of)
  3. 3 Hamilton Glaucoma Center, UCSD, La Jolla, California, USA
  4. 4 Ophthalmology, Maastricht University, Maastricht, Netherlands
  5. 5 Hamilton Glaucoma Center, Shiley Eye Institute and Department of Ophthalmology, UCSD, La Jolla, California, USA
  1. Correspondence to Harsha Laxmana Rao, Glaucoma, Narayana Nethralaya, 63, Bannerghatta Road, Bangalore 560076, India; harshalaxmanarao{at}gmail.com

Abstract

Aim To compare the repeatability of peripapillary perfusion density and flux index measurements on referenced and non-referenced optical microangiography (OMAG) scans in normal, glaucoma suspect and glaucoma eyes.

Methods In a cross-sectional study, 48 eyes (33 subjects) underwent three repeat, non-referenced peripapillary OMAG scans in the same session and 43 eyes (25 subjects) underwent three referenced peripapillary OMAG scans. In the referenced scan group, repeat scans (second and the third scan) were acquired exactly on the baseline (first) scan using the ‘track to prior scan’ option on the device. Repeatability estimates of the mean and four-sector (temporal, superior, nasal and inferior) OMAG measurements on the non-referenced and referenced scans were assessed using within-subject coefficient of repeatability (CRw) and variation (CVw).

Results CRw (%) of peripapillary perfusion density measurements (range: 2.0–4.1) on non-referenced scans were significantly higher than that on referenced scans (range: 1.4–2.7). CVw (%) on non-referenced and referenced scans ranged from 1.7 to 3.1 and from 1.2 to 2.1, respectively . CRw of flux index on non-referenced and referenced scans ranged from 4.4 to 5.8 and from 3.6 to 4.8, respectively. CVw on non-referenced and referenced scans ranged from 4.1 to 5.2 and from 3.3 to 4.5, respectively.

Conclusions Repeatability estimates of OMAG measurements were better on referenced scans compared with non-referenced scans. Perfusion density measurements had lower variability than flux index. OCTA-measured perfusion density of referenced scans is preferable for monitoring vascular change in glaucoma.

  • Diagnostic tests/Investigation
  • Glaucoma
  • Imaging

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Funding HLR: Santen (C), Allergan (C), Carl-Zeiss Meditec (C, S); SD: none; MR: none; RL: none; NKP: none; ZSP: none; SM: none; KM: Santen (C), Allergan (S), ImplanData (C); CABW: Alcon (S), Allergan (C), Pfizer (C), Santen (C); RNW: Optovue (S), Meditec-Zeiss (S), Heidelberg Engineering (S), Allergan (C), Bausch & Lomb (C), CenterVvue (S). Supported in part by R01 EY029058 (RNW) from the National Eye Institute, and an unrestricted grant from Research to Prevent Blindness (NY, New York). ‘C’ is Consultant and ‘S’ is research support.

  • Competing interests None declared.

  • Ethics approval Obtained from Ethics Committee of Narayana Nethralaya.

  • Provenance and peer review Not commissioned; externally peer reviewed.

  • Data availability statement All data relevant to the study are included in the article or uploaded as supplemental information.

Linked Articles

  • At a glance
    Frank Larkin