Skip to main content
Log in

A scleral buckle pressure gauge for continuous monitoring of intraocular pressure

  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

An implantable variable resistance pressure gauge has been constructed from a conductive elastomere in the form of a scleral buckle which is suitable for recording intraocular pressure in vivo continuously over an indefinite period of time. The similarity of the pressure transducer to the standard scleral buckles used to reduce retinal detachments suggests that it will be tolerated over a period of years without significant effect on intraocular pressure. The electrical output from these pressure gauges appears to be both well defined and of sufficient magnitude to operate a valve to control intraocular pressure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Caudell, T.P., F.M. Smolka, D.R. Eisenstein & B.L. Eisenstein. Silicone rubber applied within the eye; a preliminary study. Appl. Opt. 18: 1305–1310 (1979).

    Google Scholar 

  2. Collins, G.C. Miniature passive pressure transensor for implanting in the eye. IEEE Trans. Biomed. Eng. 14: 34 (1963).

    Google Scholar 

  3. Cooper, R.L. & D. Beale. Radio telemetry of intraocular pressure in vitro. Invest. Ophthalmol. Vis. Sci. 16: 168–171 (1977).

    Google Scholar 

  4. Couvillon, L.A., C.D. Baker & T.P. Grover. Intraocular pressure new non-invasive, continuous monitoring system. Trans. 28th American Conference on Engineering in Medicine and Biology (ACEMB). New Orleans, p. 324, Sept. 22–24 (1975).

  5. de Venicia, G. & M.D. Davis. Diurnal variation of intraocular pressure in the normal eye. Arch. Ophthalmol. 69: 752 (1963).

    Google Scholar 

  6. Drance, S.M. The significance of the diurnal tension variations in normal and glaucoma eyes. Arch. Ophthalmol. 64: 494 (1960).

    Google Scholar 

  7. Greene, M.E. & B.G. Gilman. Intraocular pressure measurement with instrumented contact lenses. Invest. Ophthalmol. 13: 229–302 (1974).

    Google Scholar 

  8. Matsumo, T., R. Nagata, M. Slashin, T. Matsuda, & S. Nakao. Measurement by holographic interferometry of the deformation of the eye accompanying changes in intraocular pressure. Appl. Opt. 17: 3538–3539 (1978).

    Google Scholar 

  9. Phelps, C.D., R.F. Woolson, A.E. Kolker & B. Becker. Diurnal variations in intraocular pressure. Amer. J. Ophthalmol. 77: 367–377 (1974).

    Google Scholar 

  10. Schepens, C.L. Scleral buckling with circling element. Trans. Amer. Acad. Ophthalmol. Otolaryngol. 68: 959–979 (1964).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wolbarsht, M.L., Wortman, J., Schwartz, B. et al. A scleral buckle pressure gauge for continuous monitoring of intraocular pressure. Int Ophthalmol 3, 11–17 (1980). https://doi.org/10.1007/BF00136208

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00136208

Keywords

Navigation