Skip to main content
Log in

Use of the argon laser to close filtering bleb leaks

  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract

We attempted to seal 15 consecutive filtering bleb leaks in 11 patients using argon laser energy. Eight leaks were at the conjunctival-corneal interface associated with a fornix-based flap, 4 leaks resulted from suture scissoring of the conjunctiva, and 3 leaks were button-holes in the conjunctiva. Thirteen leaks occurred within 2 weeks after filtering surgery, while 2 were of late onset. Argon laser parameters used were a 500-μm spot size, 0.1-s time interval, and between 500 and 1800 mW of power. Thirteen leaks were sealed after one or two laser sessions, while 2 leaks required other treatment modalities. Complications included conjunctival fenestration and transient corneal stromal opacities. This study suggests that the argon laser can be used to seal filtering bleb leaks in many patients following filtering surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Awan KJ, Spaeth GL (1974) Use of isobutyl-2-cyanoacrylate tissue adhesive in the repair of conjunctival fistula in filtering procedures for glaucoma. Ann Ophthalmol 6:851–853

    Google Scholar 

  2. Blok MDW, Kok JHC, Mil C van, Greve EL, Kijlstra A (1990) Use of the megasoft bandage lens for treatment of complications after trabeculectomy. Am J Ophthalmol 110:264–268

    Google Scholar 

  3. Brubaker RF, Pederson JE (1983) Ciliochoroidal detachment. Surv Ophthalmol 27:281–289

    Google Scholar 

  4. Fink AJ, Boys-Smith JW, Brar R (1986) Management of large filtering blebs with the argon laser. Am J Ophthalmol 101: 695–699

    Google Scholar 

  5. Fourman S, Wiley L (1989) Use of a collagen shield to treat a glaucoma filter bleb leak. Am J Ophthalmol 109:673–674

    Google Scholar 

  6. Hill RA, Aminlari A, Sassani JW, Michalski M (1990) Use of a symblepharon ring for treatment of over-filtration and leaking blebs after glaucoma filtration surgery. Ophthalmic Surg 21:707–710

    Google Scholar 

  7. Kijiwara K (1990) Repair of a leaking bleb with fibrin glue. Am J Ophthalmol 109:599–601

    Google Scholar 

  8. Ruderman JM, Allen RC (1985) Simmon's tamponade shell for leaking filtration blebs. Arch Ophthalmol 103:1708–1710

    Google Scholar 

  9. Petursson GJ, Fraunfelder FT (1979) Repair of an inadvertent buttonhole of leaking filtration bleb. Arch Ophthalmol 97: 926–927

    Google Scholar 

  10. Shields MB (1987) Textbook of glaucoma. Williams and Wilkins, Baltimore, pp 474–476

    Google Scholar 

  11. Stewart WC (1990) Clinical practice of glaucoma. Slack Inc, Thorofare, p 371

    Google Scholar 

  12. Sugar HS (1971) Treatment of hypotony following filtering surgery for glaucoma. Am J Ophthalmol 71:1023–1033

    MathSciNet  MATH  Google Scholar 

  13. Tomlinson CP, Belcher CD, Smith PD, Simmons RJ (1987) Management of leaking filtration blebs. Ann Ophthalmol 19:405–408

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Supported in part by a grant from Research to Prevent Blindness, Inc.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hennis, H.L., Stewart, W.C. Use of the argon laser to close filtering bleb leaks. Graefe's Arch Clin Exp Ophthalmol 230, 537–541 (1992). https://doi.org/10.1007/BF00181775

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00181775

Keywords

Navigation