Abstract
The ophthalmic rod (OR) is a new drug delivery system, intended as an alternative to conventional therapy in ophthalmology. The rod is made of a nontoxic plastic. It is dipped into a drug solution which after drying forms a thin homogeneous coating. The OR is then packed and sterilized by gamma radiation. The effects of radiation on the contents of the drugs were studied using IR, UV, and thin-layer chromatography (TLC). Sterility, dose variation, and simulated drug delivery in vitro were tested. Pure drugs were used; no preservatives were included. To deliver the drug, the tip of the rod is introduced into the conjunctival sac and rubbed against the palpebral conjunctiva of the lower lid. ORs with tropicamide, oxybuprocaine HCl, pilocarpine HCl, and fluorescein sodium were used. The behavior of the drugs administered by this system was compared with eyedrops. Results of trials with three drugs, i.e., tropicamide, oxybuprocaine HCl, and fluorescein sodium on ORs applied to the eyes of humans and those of the rabbit are discussed.
Similar content being viewed by others
References
Alani SD (1978) The ophthalmic rod: description of a disposable ophthalmic drug delivery device. Acta Pharm Suec 15:237–240
Boberg-Ans J (1955) Experience in clinical examination of corneal sensitivity. Br J Ophthalmol 39:705–726
Bowman FW, Knoll EW, White M, Mislivec P (1971) Survey of microbial contamination of ophthalmic ointments. J Pharm Sci 61:532–535
Burstein NL, Anderson JA (1985) Corneal penetration and ocular bioavailability of drugs. J Ocul Pharmacol 1:309–326
Coad CT, Osato MS, Wilhelmus KR (1984) Bacterial contamination of eyedrop dispensers. Am J Ophthalmol 98:548–551
Collie HB (1986) Ultrastructural changes to corneal stromal cells due to ophthalmic preservatives. Acta Ophthalmol (Copenh) 64:72–78
Collin HB, Grabsch BE (1982) The effect of preservatives on the healing rate of the rabbit cornea epithelium after keratectomy. Am J Optom Physiol Opt 59:215–222
Hayden AL, Sammul OR, Selzer GB, Carol J (1962) Infrared, ultraviolet and visible absorption spectra of some USP and NF reference standards and their derivatives. J Assoc Off Anal Chem 45:797
Kilp H, Brewitt H (1984) Cytotoxicity of preservatives: a scanning electron microscopic and biochemical investigation. Chibret Int J Ophthalmol 1:4–20
Lachman L (1968) The instability of antimicrobial preservatives. Bull Parenter Drug Assoc 22:127–144
Macdonald R Jr, Keller KF, Blatt MM, Cox HB (1969) Sterility and concentration of pilocarpine-solutions. Am J Ophthalmol 68:1099–1102
Mitra AK, Mikkelson TJ (1987) Ophthalmic solution buffer systems. Int J Pharmacol 37:19–26
Nash RA (1974) Radiosterilized tetracycline ophthalmic ointment. Bull Parenter Drug Assoc 28:181–187
Powell EGP (1985) The cytotoxic activity of ophthalmic preservatives. J Pharm Pharmacol 37 [Suppl]:63
Russel AD, Jenkins J, Harrison IH (1967) The inclusion of antimicrobial agents in pharmaceutical products. Adv Appl Microbiol 9:1–38
Sharkey MF, Anders CN, Snow SW, Major A, Kram T, Warner V, Alexander TG (1968) An index of electronic spectra. J Assoc Off Anal Chem 51:1124
Trigger DJ, Caldwell ADS (1968) Studies on some radiationsterilized single-dose ophthalmic preparations. J Hosp Pharmacol 25:259–265
Author information
Authors and Affiliations
Additional information
This project was supported by the Swedish Board for Technical Development, Stockholm, Sweden (no. 74-5056/Ra)
Rights and permissions
About this article
Cite this article
Alani, S.D. The ophthalmic rod: A new ophthalmic drug delivery system I. Graefe's Arch Clin Exp Ophthalmol 228, 297–301 (1990). https://doi.org/10.1007/BF00920050
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00920050