Corneal thickness and corneal endothelium in normotensive subjects with unilateral exfoliation syndrome

  • Clinical Investigation
  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract 

Purpose: To examine the central corneal thickness (CCT) and corneal endothelium in both eyes of patients with unilateral exfoliation syndrome (EXS). To determine the effect of CCT on the measurement of intraocular pressure (IOP). Methods: In this cross-sectional clinical study, comparisons were made of CCT (Humphrey Ultrasonic Pachometer), corneal endothelial cells (Keeler-Konan contact specular microscope) and IOP (Goldmann applanation tonometer) between the exfoliative (E) and fellow non- exfoliative (NE) eyes in 40 normotensive patients with unilateral EXS. The CCT was used to obtain a corrected value for the IOP. Results: The E eyes had significantly higher values for CCT (0.528±0.030 vs 0.523±0.032 mm, P<0.01) and IOP (15.7±3.6 vs 14.4±2.9 mmHg, P<0.001) than the fellow NE eyes. The paired E and NE eyes did not differ in endothelial cell density (2779±540 vs 2870±386 cells/mm2), in the coefficient of variation of cell size (0.25±0.03 vs 0.26±0.03) or in the frequency of hexagonal cells (80.5±6.5 vs 82.0±5.0%). After correcting IOP for CCT, the E eyes still had significantly higher IOP than the NE eyes (15.1±4.4 vs 14.2±3.7 mmHg, P<0.05). Conclusion: Normotensive eyes with early EXS did not have quantitative (cell density) or qualitative (variation in cell size, frequency of hexagonal cells) morphological changes in corneal endothelium, but had higher values for IOP and CCT. After correcting IOP for CCT, the E eyes still had significantly higher IOP than the fellow NE eyes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 16 December 1999 Revised: 20 March 2000 Accepted: 21 March 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Puska, P., Vasara, K., Harju, M. et al. Corneal thickness and corneal endothelium in normotensive subjects with unilateral exfoliation syndrome. Graefe's Arch Clin Exp Ophthalmol 238, 659–663 (2000). https://doi.org/10.1007/s004170000159

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004170000159

Keywords

Navigation