Functional imaging of the retinal microvasculature by Scanning Laser Doppler Flowmetry

  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

Purpose: to image functionally perfused retinal vessels and to assess quantitatively the intercapillary space of the retinal microvasculature.Method: The base offunctional imaging and the quantitative assessment of the retinal vasculature is the two-dimensional map of the retina encoded by the laser Doppler frequency shift. By Scanning Laser Doppler Flowmetry (HRF. Heidelberg Engineering) the laser Doppler frequency shift of 16.384 retinal sites (256 pixels × 64 lines, spatial resolution10 μm) of a retinal area of 2.7 × 0.7 mm was gained. The image processing was performed by a recently described algorithm (AFFPIA). Using the data of the laser Doppler frequency shift of every retinal site, a color-coded retinal image was establishedshowing perfused vessels and capillaries. By automatic pattern analysis of this image vessels and capillaries were identified and segmented. Based on this image the distances in [μm] of every retinal site to the next vessel or capillary were calculated ("distanceto next capillary''). The functional imaging of the retinal perfusion was demonstrated in (1) normal retina, (2) retinal arterial occlusion, and (3) proliferative retinopathy. Intraobserverreliability of the quantitative assessment of the parameter ``distance to next capillary'' was estimated by measuring 10 eyes of 10 subjects at 5 different days by one observer. Interobserver reliability of the quantitative assessment was evaluated by analysing10 perfusion maps by 5 different operators. In 93 eyes of 71 normal subjects (mean age 40.4 μ 15 years) the juxtapapillary retina was quantitatively evaluated.Results: Qualitative evaluation: The functional images of the retinal perfusion of eyes with normal retina, with retinal arterial occlusion, and with proliferative retinopathy correspondedwell with the fluorescein angiography. Perfused vessels and capillaries became visible in a high local resolution. Quantititative assessment: The coefficient of reliability of the introobserver and interobserver reproducibility of the parameter ``mean distance to next capillary'' was 0.74, and 0.95, respectively. The quantitative assessment of the perfusion showed that the major part of the retinal sites (>700%) had distancesto the next capillary lower than 30 μm 46% of the retinal area had distances to the next capillary from 0–20 lμm 26% of the retina had distances from 20–30 μm, 12% of the retina had distances from 30–40 μm 7% of the retina had distances from 40–50 μm, 4% of the retina had distances from 50–60 μm, and 4% of the retinal sites showed distances to the next capillary greater than 60 μm. The mean distance tothe next capillary or vessel was calculated with 21 ± 6.5 μm.Conclusion: By non-invasive Scanning Laser Doppler Flowmetry in combination with adequate softwareit is possible to perform a functional imaging of the retinal vasculature and to measure all index for the functional density of retinal capillaries and vessels.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Arend O, Remky A, Redbrake C, Arend S, Wenzel M, Harris A. Retinal hemodynamics in patients with normal pressure glaucoma. Quantification with digital laser scanning fluorescein angiography. Ophthalmologe 1999; 96(1): 24–29.

    Google Scholar 

  2. Michelson G, Welzenbach J, Pal I, Harazny J. Automatic full-field perfusion image analyze. Brit J Ophthalmol 1998; 1294–1300.

  3. Michelson G, Zinser G, Schmauß B. Verfahren und Gerät zur Messung der Fließ geschwindigkeit, insbesondere des Blutes. 1.6.94, European Patent No. 94108430.3.

  4. Michelson G, Groh M, Langhans M, Schinauss B. Zweidimensionale Kartierung der retinalen und papillären Mikrozirkulation mittels Scanning-Laser-Doppler-Flowmetrie. Klin Monatsbl Augenheilkunde 1995; 207: 180–190.

    Google Scholar 

  5. Michelson G, Scmauß B. Two-dimensional mapping of the juxtapapillary perfusion by scanning laser Doppler flowmetry. British J Ophthalmol 1995; 79: 1126–1132

    Google Scholar 

  6. Michelson G, Schmauß B, Langhans MJ, Harazny J, Groh MJM. Principle, validity, and reliability of scanning laser Doppler flowmetry. J Glaucoma 1996; 5: 99–105.

    Google Scholar 

  7. Bonner RE, Nossal R. Principles of laser-Doppler flowmetry. In Laser-Doppler Blood Flowmetry, Vol. 7. Sheperd Alber P, Öberg P Ake (eds) Boston: Kluwer Academic Publishers, 1990; 17–45.

    Google Scholar 

  8. Strenn K. Menapace R, Rainer G, Findl O, Woltzt M, Schmetterer L. Reproducibility and sensitivity of scanning laser Doppler flowmetry during graded changes in Po2. Br J Ophthalmol 1997; 81: 360–364.

    Google Scholar 

  9. Chauhan B. Confocal scanning laser Doppler flowmetry of the retina and optic nerve head. In: Anderson DR, Drance SM (eds)Encounters in Glaucoma Research 3. How to Ascertain Progression and Outcome. Amsterdam: Kugler 1996; 263–276.

    Google Scholar 

  10. Chauhan B, Smith FM. Confocal scanning laser Doppler flowmetry: experiments in a model flow system. J Glaucoma 1997; 6: 237–245.

    Google Scholar 

  11. Pál I. Michelson G, Niemann H, Welzenbach J: Erkennung von Mikrozirkulationsstörungen der Netzhaut mittels "Scanning Laser Doppler Flowmetrie". In Lehmann T, Scholl I, Spitzer K (eds) Bildbverarbeitung für die Medizin: Algorithmen-Systeme-Anwendungen Proceedings des Aachener Workshops, Verlag Der Augustinus Buchh., Aachen, Nov. 1996; 89–94.

    Google Scholar 

  12. Kutka R, Stier S. Blood vessel and feature extraction based on direction fields. In: Proceedings of the Workshop on Image Registration and Segmentation, Brussels, April 1994.

  13. Zhou RW, Quek C. Ng GS. A novel single-pass thinning algorithm and an effective set of performance criteria. IEEE Trans on Pattern Recognition Letters 1995; 16: 1267–1275.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Michelson, G., Welzenbach, J., Pal, I. et al. Functional imaging of the retinal microvasculature by Scanning Laser Doppler Flowmetry. Int Ophthalmol 23, 327–335 (2001). https://doi.org/10.1023/A:1014402730503

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1014402730503

Navigation