Detection of optic neuropathy in glaucomatous eyes with normal standard visual fields using a test battery of short-wavelength automated perimetry and pattern electroretinography

Ophthalmology. 2002 Jul;109(7):1350-61. doi: 10.1016/s0161-6420(02)01100-4.

Abstract

Purpose: To evaluate the clinical use of a test battery of short-wavelength automated perimetry (SWAP), frequency-doubling technology (FDT) perimetry, and pattern-electroretinography (PERG) in patients with definite primary open-angle glaucoma (POAG) but normal results on standard automated perimetry (SAP).

Study design: Prospective, comparative, observational case series.

Participants: Thirty-six patients with POAG with standard visual field defects in one eye and normal standard visual fields in the contralateral eye and 36 normal controls were enrolled.

Main outcome measures: SWAP, PERG, FDT, and SAP were performed in all eyes, and global indices and amplitudes were used for statistical analysis.

Results: When contralateral POAG eyes with asymmetric glaucomatous damage was compared, a paired t test showed significant differences in SAP mean deviation (MD) (P < 0.0001), SWAP-MD (P = 0.0003), FDT-MD (P = 0.0008), and PERG amplitudes (P < 0.0001). When comparing between POAG eyes with normal results on SAP and normal controls, Student's t test showed significant differences for SWAP-MD (P < 0.0001), FDT-MD (P = 0.0006), PERG N1P1-amplitude (P = 0.0486) and P1N2-amplitude (P < 0.0001); receiver operating characteristic analysis revealed promising accuracy for SWAP-MD of 73.6% (P < 0.0001). SWAP-MD (P < 0.0001) and FDT-MD (P < 0.0001) correlated significantly with SAP-MD and with each other (range, P < 0.0001 to P = 0.0020). Regression analysis revealed that PERG P1N2-amplitude could improve the power of SWAP-MD from 73.6% to detect early POAG in eyes with normal results on SAP to an accuracy of 81.9%.

Conclusions: A test battery of SWAP-MD and PERG P1N2-amplitude could detect glaucomatous optic neuropathy in POAG eyes with normal standard visual fields, whereas FDT-MD and SWAP-MD significantly correlated with each other and with SAP-MD. All tests were able to detect the eye with the more severe glaucomatous optic neuropathy in patients with asymmetric POAG.

Publication types

  • Clinical Trial
  • Comparative Study
  • Evaluation Study

MeSH terms

  • Electroretinography / methods*
  • Female
  • Glaucoma, Open-Angle / diagnosis*
  • Humans
  • Intraocular Pressure
  • Male
  • Middle Aged
  • Optic Disk / pathology*
  • Optic Nerve Diseases / diagnosis*
  • Pattern Recognition, Visual
  • Prospective Studies
  • Vision Disorders / diagnosis
  • Visual Acuity
  • Visual Field Tests / methods*
  • Visual Fields*