A THC:YAG laser (thulium, holmium, chromium-doped YAG crystal) was used to create thermal sclerostomies in 21 glaucomatous eyes of 19 patients. The laser is a long-pulsed (300 microsec), compact, self-contained, solid state laser operating in the near infrared (2.1 mu). A 1-mm conjunctival stab incision was made 12 mm away from the sclerostomy site to allow entry of a specially designed 22-gauge (712 mu) optic probe that delivers energy at a right angle to the long axis of the fiber. Probe insertion produced minimal disturbance of the conjunctiva. Pulse energies of 80 mJ to 120 mJ were used with a repetition rate of 5 pulses/second. Total energy levels to produce full-thickness sclerostomies ranged from 1.4 to 4.8 J. Subconjunctival 5-fluorouracil injections were administered in 15 eyes. At 3 months the mean intraocular pressure of successful cases (16) was 14 mmHg (range, 9 to 22 mmHg). Of successful cases, the mean intraocular pressure at 6 months was 13 mmHg (range, 2 to 22 mmHg). Five cases failed within the initial 3 months, and 3 additional cases failed by 6 months. The authors conclude that this full-thickness sclerostomy technique may simplify filtering surgery without anterior chamber instrumentation and with minimal conjunctival trauma.