Article Text

Download PDFPDF

Sponge delivery variables and tissue levels of 5-fluorouracil
  1. Mark R Wilkinsa,b,
  2. Nicholas L Occlestona,
  3. Aachal Kotechaa,b,
  4. Lorraine Watersa,
  5. Peng T Khawa,b
  1. aWound Healing Research Unit, Department of Pathology, Institute of Ophthalmology, London, bGlaucoma Unit, Moorfields Eye Hospital, London
  1. Mr Peng T Khaw, Wound Healing Research Unit, Department of Pathology, Institute of Ophthalmology, Bath Street, London, EC1V 9EL

Abstract

AIM To study how the delivery of 5-fluorouracil (5-FU) to ocular tissues is affected by altering delivery variables.

METHOD Sponge(s) soaked in radiolabelled 5-FU were placed between the conjunctiva and sclera of pig eyes. Application time, sponge size, sponge make (Altomed, Weck, Merocel), and 5-FU concentration were varied. Conjunctival and scleral tissue levels were determined in samples taken from the application site.

RESULTS Dose-response curves for scleral and conjunctival 5-FU levels against application time showed increasing tissue levels that reached a plateau after 2–3 minutes. Application beyond 3 minutes did not increase tissue levels. There was no difference in tissue levels between 7×4 and 3.5×2 mm sponges. Altomed sponges produced 5-FU tissue levels that were twice as high as those obtained with Weck-cell (p<0.01) or Merocel (p<0.02) sponges. Changing the 5-FU concentration from 25 mg/ml to 6.25 mg/ml reduced the conjunctival concentration by a factor of 3.5 (p<0.003).

CONCLUSION Application time up to 3 minutes, sponge make, and 5-FU concentration can have a large effect on the tissue delivery of 5-FU. Application time beyond 3 minutes, using 3.5×2 mm or 7×4 mm sponges, and replacing sponges every minute did not have a significant effect on tissue levels. This study models the effect that different variables can have on the ocular tissue levels of an antimetabolite applied intraoperatively.

  • sponge delivery
  • 5-fluorouracil

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

The use of antimetabolites has revolutionised filtration surgery offering improved success rates in high risk patients.1-4 Initially mitomycin C and now 5-fluorouracil (5-FU) are both applied intraoperatively using a sponge soaked in the antimetabolite. However, the use of antimetabolites is associated with side effects. The thin avascular blebs associated with their use can lead to hypotony, bleb leaks, and endophthalmitis.1 5-12Conversely, some blebs may fail despite mitomycin C treatment, some of the variation in response to antimetabolites being due to variations in delivery technique.

In an attempt to “titrate” the antiscarring effects of intraoperative antimetabolites investigators have varied application technique. Clinical studies have assessed the effect of varying duration of application,13-15 concentration of agent,13 16-18 and irrigation,19 but not sponge type or treatment area. Non-clinical studies have altered sponge type20 and area.21 We designed a study to investigate the effects of application time, application technique, sponge type, and size on tissue levels of 5-FU in an experimental model.

Method

Fresh pig eyes (Dalehead Foods, Cambridgeshire) were removed from carcasses on the morning of slaughter and transported to the laboratory. Dissolving a pellet of 14C 5-FU (Sigma) in 2 ml distilled water made up a stock solution of 14C labelled 5-FU. For each application technique, adding 5 μl of stock to 3 ml of 25 mg/ml 5-FU (David Bull Laboratories) created a radioactive 5-FU solution. Preliminary work showed that this dilution was sufficient to produce detectable levels in ocular tissue following application.

Each eye that was tested was placed under an operating microscope and rotated until undisturbed conjunctiva overlying sclera was visible superiorly. A limbal based flap was dissected and, depending on the experiment, one or more sponges soaked in 14C 5-FU placed between the conjunctiva and sclera. For techniques 1–4 a 25 mg/ml14C 5-FU solution as detailed above was used. For technique 5 the solution was diluted 1:4 using phosphate buffered saline. The posterior edge of the conjunctiva was held down using a muscle clamp. The following application techniques were then performed:

(1)

Single 7×4 mm Altomed sponge applied for 0, 1, 2, 3, 5, and 10 minutes.

(2)

Single 3.5×2 mm Altomed sponge applied for 5 minutes, compared with single 7×4 mm Altomed sponge applied for 5 minutes.

(3)

7×4 mm Altomed sponge: one sponge applied for 1 minute replaced every minute for 5 minutes, compared with single 7×4 mm Altomed sponge applied for 5 minutes.

(4)

Single Merocel, Weck, or Altomed 7×4 mm sponge applied for 5 minutes.

(5)

Single 7×4 mm Altomed sponge soaked in 6.25 mg/ml14C labelled 5-FU solution applied for 5 minutes, compared with single 7×4 mm Altomed sponge soaked in 25 mg/ml 14C labelled 5-FU solution applied for 5 minutes.

 Following the application all sponges were removed and the treated area irrigated with 20 ml phosphate buffered saline. Conjunctiva overlying the treated area was removed from all eyes using an 8.25 mm corneal trephine. Additional scleral samples were taken from groups 1 to 3. Sclera underlying the treated area was removed using an 8.25 mm trephine. To assess regional tissue 5-FU levels conjunctival and scleral trephines were taken from either side of the treated area (Fig1) after single 5 minute applications of 7×4 mm and 3.5×4 mm Altomed sponges. Five fresh eyes were used for each change in application time, technique, or sponge type. Altomed sponges were supplied as 7 mm wide strips. These were cut into 4 mm wide pieces using a purpose made punch.22 Weck and Merocel sponges were supplied on wider strips that were reduced to 7 mm in width and then passed through the same punch. Quartering 7×4 mm sponges produced the 3.5×2 mm sponges.

Figure 1

Sites of conjunctival and scleral biopsies. Box shows site of sponge application.

Figure 10

Scleral tissue level of 14C 5-FU following a single 5 minute application of an Altomed sponge soaked in either 25 mg/ml or 6.25 mg/ml 14C 5-FU solution.

Figure 2

Conjunctival tissue level of 14C 5-FU against duration of single application of Altomed sponge.

Figure 3

Scleral tissue level of 14C 5-FU against duration of single application of Altomed sponge.

Figure 4

Regional conjunctival tissue level of 14C 5-FU following single 5 minute application of either 7×4 mm or 3.5×2 mm Altomed sponge. Sites 1, 2, and 3 are shown in Figure 1.

Figure 5

Regional scleral tissue level of 14C 5-FU following single 5 minute application of either 7×4 mm or 3.5×2 mm Altomed sponge. Sites 1, 2, and 3 are shown in Figure 1.

Figure 6

Conjunctival tissue level of 14C 5-FU following either a single Altomed sponge applied for 5 minutes or an Altomed sponge replaced every minute for 5 minutes.

Figure 7

Scleral tissue level of 14C 5-FU following either a single Altomed sponge applied for 5 minutes or an Altomed sponge replaced every minute for 5 minutes

Figure 8

Conjunctival tissue level of 14C 5-FU following a single application using a Weck, Altomed, or Merocel sponge.

Figure 9

Conjunctival tissue level of 14C 5-FU following a single 5 minute application of an Altomed sponge soaked in either 25 mg/ml or 6.25 mg/ml 14C 5-FU solution.

 Each trephined tissue sample was placed in a preweighed scintillation vial that was then weighed again to calculate the weight of the specimen. Two ml of Soluene (Cambridge-Packard) were added to the vial. The vial was then incubated at 37°C overnight to encourage the tissue to dissolve. After the tissue had dissolved, 10 ml of Hionic-fluor (Cambridge-Packard) was added and the vial then passed through a Cambridge-Packard scintillation counter. The resulting count was divided by the tissue weight to achieve a count per gram of tissue. This was taken to be directly proportional to the amount of 5-FU absorbed by the tissue.

Results

DURATION OF APPLICATION—A SINGLE ALTOMED SPONGE APPLIED FOR INCREASING TIME PERIODS (FIGS 2 AND 3)

A dose-response curve for 5-FU tissue levels in both sclera and conjunctiva is shown. The changes in tissue levels are significant using one way analysis of variance (conjunctiva p<0.001, scleral p<0.001). Both curves show little improvement in tissue levels beyond a 3 minute single application. There was no significant difference between the 2, 3, 5, and 10 minute 14C 5-FU conjunctival and scleral levels. There was marked variability in the conjunctival tissue levels beyond 1 minute. A Levene test for homogeneity of variance across the time points was significant for the conjunctival tissue levels (p=0.02) but not for the scleral ones (p=0.056). The Levene test, which is not dependent on the assumption of normality, assesses the equality of group variances. A significant value for the conjunctival tissue levels suggests that there were real differences in the variance at different time points.

SPONGE AREA—A SINGLE 7×4 MM ALTOMED SPONGEV A SINGLE 3.5×2 MM ALTOMED SPONGE, BOTH APPLIED FOR 5 MINUTES (FIGS 4 AND 5)

There was no significant difference in scleral and conjunctival14C 5-FU levels at the application site with the two sponge sizes. There was a marked fall off in scleral and conjunctival tissue levels either side of the application site which was significant whether a 7×4 mm or 3.5×2 mm sponge was used.

SPONGE REPLACEMENT—A SINGLE ALTOMED SPONGE APPLIED FOR 5 MINUTES COMPARED WITH REPLACING THE SPONGE EVERY MINUTE FOR 5 MINUTES (FIGS 6 AND 7)

Replacing the sponge every minute did not significantly increase either conjunctival or scleral 14C 5-FU levels.

SPONGE TYPE—5 MINUTE SINGLE APPLICATIONS OF THREE SPONGE TYPES (FIG 8)

Mean conjunctival tissue levels of 14C 5-FU were significantly different across the three sponge types (one way ANOVA p=0.005). Mean conjunctival tissue levels following application using an Altomed sponge were at least double those using Weck-cell or Merocel sponges. (Weck-cell v Altomed p=0.01, Merocel v Altomed p=0.02). Using the Levene test for homogeneity of variance showed that the variance of tissue distribution was not the same for each sponge type p=0.039.

TECHNIQUE 5 CONCENTRATION (FIGS 9 AND 10)—SINGLE 5 MINUTE APPLICATION OF A 7×4 MM ALTOMED SPONGE SOAKED IN EITHER 25 MG/ML OR 6.25 MG/ML 14C 5-FU

Reducing the concentration by a factor of 4 reduced the conjunctival 14C 5-FU tissue levels by a factor of 3.5 (t test p=0.003).

Discussion

Clinicians have sought to titrate the dose of intraoperative antimetabolite delivered to tissues against a patient's risk of scarring following filtration surgery. The most commonly used methods for varying intraoperative antimetabolite delivery are to alter exposure time and antimetabolite concentration. A recent survey23 of antimetabolite use among American and Japanese glaucoma surgeons found a wide range in application time (0.5 seconds–7 minutes) and concentration (0.1–0.8 mg/ml) of mitomycin C for the same clinical situation, with no clear logic for the choice in many cases. We have assessed the effect of varying multiple delivery variables on tissue levels of the antimetabolite 5-FU.

While to our knowledge there have been no animal studies looking at exposure time there have been two prospective studies on humans where intraoperative exposure time to an antimetabolite has been varied. Shinet al 14 15 randomised 174 patients undergoing trabeculectomy at the same time as cataract extraction to receive either no mitomycin or a 1, 3, or 5 minute intraoperative application of 0.5 mg/ml mitomycin C. There was no significant difference in success rates between the control and mitomycin C groups, nor within the 1, 3, and 5 minute subgroups. Robinet al 13 randomised phakic trabeculectomy patients to receive either placebo, 0.2 mg/ml mitomycin C for 2 minutes, 0.2 mg/ml mitomycin C for 4 minutes, or 0.4 mg/ml mitomycin C for 4 minutes. They found no significant difference in successful outcomes between the three application techniques for mitomycin C. However, no power calculation for detecting subgroup differences is quoted and it may well be that the study was not large enough to detect a difference. A retrospective review of cases7 treated with mitomycin C for 3.5–7 minutes found that those patients treated for 3.5 minutes had less hypotony than those treated for longer. However a case-control study11comparing 0.2 mg/ml mitomycin C applied for either 2 or 5 minutes found no difference in success rates or complications. Table 1 highlights other case series that have included patients where the duration of intraoperative exposure to mitomycin C varied.18 24-28These studies have not analysed their results according to duration of exposure. In this study increasing the duration of application of a single 14C 5-FU soaked sponge produces a dose-response curve with maximal scleral and conjunctival levels after 2–3 minutes. Beyond 1 minute there is a large variability in the amount of 5-FU delivered to tissues. The levels appear to plateau between 2 and 3 minutes with no significant increase in tissue concentration after this time. Greater variability was seen in the conjunctival tissue levels than in the scleral levels. This may be related to differences in the tissues themselves but may also be related to technique. In preparing a conjunctival flap the conjunctiva is stretched and may end up having a variable thickness. In contrast the sclera is largely untouched.

Table 1

Summary of application techniques of intraoperative antimetabolites

Human13 and animal29 30 studies have both used antimetabolite application regimens that involved replacing sponges. Chen's mitomycin C technique involves replacing sponges every minute.17 However, in no study have comparisons between a single sponge and replacing sponges been made. In our model replacing a sponge every minute for 5 minutes did not improve conjunctival and scleral levels compared with applying a single sponge for 5 minutes. Multiple replacement of a sponge may increase the risk of spreading antimetabolite onto non-targeted areas such as the conjunctival wound edge. Leaving a single soaked sponge may be adequate.

A study on a rabbit model of filtration surgery has looked at the effect of sponge area on bleb survival when 0.4 mg/ml mitomycin C is applied intraoperatively.21 A change in dry Weck-cell sponge size from 4×2 mm to 8×10 mm produces an increase in bleb area, height, and survival. In contrast, our study shows that changing the size of an Altomed sponge from 3.5×2 mm to 7×4 mm does not improve the tissue levels of 14C 5-FU either at the application site or at the sites either side of the application point. It may well be that using live rabbits, an alternative antimetabolite, Weck sponges, and increasing the sponge size by a factor of 10 may produce a more significant effect. In this study the largest used sponge was 7×4 mm; this reflects the largest size sponge currently in use at Moorfields Eye Hospital. Reducing the area of this sponge by a factor of 10 would generate a tiny sponge that is not clinically relevant.

Two animal studies29 30 have looked at the focality of intraoperative antimetabolite treatment. Both studies applied intraoperative 5-FU or mitomycin C between the sclera and conjunctiva of rabbits undergoing filtration surgery. In both papers 4×1 mm Weck-cell sponges were used. Tissue biopsies taken from sites 90 and 180 degrees from the treated area and cultured for fibroblast outgrowth showed normal outgrowth. In one study30 it was pointed out that biopsies taken 90 degrees from the centre of the treatment area were only 1–2 mm from the edge of the treatment area. Clearly there is a rapid fall off in clinical effect when either 5-FU or mitomycin C is applied intraoperatively. Our findings confirm that there is a rapid fall off in tissue 5-FU levels either side of the treated area in this model and that treatment is relatively focal.

The papers listed in Table 1 have all used sponges to apply intraoperative antimetabolites. The brand used varies considerably while in many cases no brand is specified. Previous work has looked at the absorption and release of mitomycin C solution by four brands of surgical spear.20 Merocel sponge spears were shown to absorb significantly more solution than the other brands that included Weck-cell but not Altomed. However, saturated Weck-cell spears released more solution when placed on filter paper than did the other three. Our results compared three different sponge makes with the same dry cross sectional area and found that Altomed sponges deliver significantly more 14C 5-FU and with less variability than Weck-cell or Merocel sponges. This is important because if surgeons change sponges they may get different clinical effects depending on the sponge type used. Discussions with the manufacturers of Altomed sponges failed to yield any explanation for their delivery properties

In their review of American and Japanese clinical practice Chenet al23 showed that most surgeons altered application time rather than antimetabolite concentration between clinical situations. Two prospective studies13 16 have compared different mitomycin C concentrations applied for the same time. Neither found a difference in success rates. Both studies found that cataract progression was higher in the arm using a higher concentration of mitomycin C. A large case series18 compared patients receiving a 3–5 minute application of either 0.2 mg/ml or 0.5 mg/ml mitomycin C. No difference was found in IOP or complication rates. No studies have compared the effect of different concentrations of 5-FU. Our study shows that diluting the 25 mg/ml 5-FU solution by a factor of 4 significantly reduces the conjunctival levels by a factor of 4. Our study suggests that it may be more logical to vary concentrations rather than delivery time. Delivery times less than 2–3 minutes are on the exponential part of the uptake curve and may therefore give rise to large variability in delivery.

Consistently successful surgery requires the control of as many variables as possible. Papers describing the application of intraoperative antimetabolites usually mention antimetabolite concentration and application time. Our work confirms that these variables are important in determining tissue delivery of 5-FU, although applying a sponge soaked in 5-FU beyond 3 minutes is unlikely to be useful. The lesser quoted and variable (Table 1) properties of types of sponge can alter tissue delivery by as much as 100%. Our study has limitations because it was carried out on cadaver eyes. We would not expect the uptake of drug to be very dissimilar in a live animal because of the limited blood flow in the tissues involved.

Understanding the effect that particular application factors have, allows the ophthalmologist to have more control on the amount of antimetabolite delivered to tissues. This should give more reproducible results in the same clinical situation while permitting the dose delivered in high risk cases to be better controlled. If studies from different centres are to be compared then it is important that delivery variables are standardised.

Acknowledgments

Financial interest: None of the authors had any commercial or proprietary interest in any of the products discussed in the article.

Supported by MRC Grant G9330070, International Glaucoma Association.

Presented in part at the Association for Research in Vision and Ophthalmology Meeting, Fort Lauderdale, Florida, 1997.

References