Article Text

This article has a correction. Please see:

Download PDFPDF
Influence of cataract on optical coherence tomography image quality and retinal thickness
  1. M E J van Velthoven1,
  2. M H van der Linden2,
  3. M D de Smet1,
  4. D J Faber3,
  5. F D Verbraak1
  1. 1Department of Ophthalmology, Academic Medical Centre, Amsterdam, The Netherlands
  2. 2OMC Haarlem, Haarlem, The Netherlands
  3. 3Laser Centre, Academic Medical Centre
  1. Correspondence to: M E J van Velthoven Department of Ophthalmology, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands; m.e.vanvelthoven{at}amc.uva.nl

Abstract

Background: As optical coherence tomography (OCT) is widely used for diagnosis and monitoring of ocular pathology, especially in the elderly people, the influence of cataract on image quality and macular retinal thickness was studied.

Methods: In 29 patients scheduled for cataract surgery, preoperative and postoperative OCT scans were obtained. Cataracts were categorised as nuclear, posterior or cortical. Parameters for image quality (signal-to-noise ratio (SNR)) and signal strength and macular thickness were compared. A three-level expert grading scale was used to evaluate the discriminative abilities of SNR and signal strength.

Results: Nuclear cataracts (n = 12) provided better preoperative scans (higher SNR/signal strength) than posterior (n = 7) and cortical (n = 10) cataracts (p<0.004). Postoperatively SNR and signal strength increased significantly in all patients (p<0.001). The SNR was better at discriminating poor from acceptable and good scans than signal strength (area under the receiver operating curve: 0.879 and 0.810, respectively). Postoperative macular thickness overall showed a significant increase (p = 0.005), most evident in patients with posterior cataracts (p = 0.028).

Conclusions: OCT imaging is influenced by cataract; image quality is reduced preoperatively and macular thickness measurements are slightly increased postoperatively. In individual patients, OCT scans remain reliable for gross clinical interpretation, even in the presence of cataract.

  • CMO, cystoid macular oedema
  • LOCS, Lens Opacities Classification System
  • OCT, optical coherence tomography
  • SNR, signal-to-noise ratio

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Competing interests: None.

  • Published Online First 19 July 2006

Linked Articles

  • PostScript
    BMJ Publishing Group Ltd.BMA House, Tavistock Square, London, WC1H 9JR